Click here to make tpub.com your Home Page

Page Title: Figure 4. Locations Transformers B I and B2
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Navigation Ground Speed Transformer BI Coarse Position
Up
TB-11-5995-207-35-1 Calibration Procedure for Simulator-Monitor SM-567/APS-94D Manual
Next
Navigation Drift Transformer B2 Fine Position.

Figure 4. Locations Transformers B I and B2
(7)  Check NAVIGATION GROUND SPEED
9.  Navigation Ground Speed Transformer BI Fine
dial indication. The dial should indicate 225 -412 dial
Position. a. Performance Check.
division.
(1)
Deenergize 115 vac, 400 Hz primary power
b. Adjustments.
circuit.
(1)  Set NAVIGATION GROUND SPEED dial at
(2)  Disconnect electronic voltmeter from barrier
225 and lock dial at this setting with dial lock (fig. 1).
strip and disconnect and remove all barrier strip jumper
wires.
(2)  Refer to figure 4. Loosen the three clamp
screws that secure case of transformer B1.
(3)  Install jumper wires between terminals B and
J, A and C, and A and II of barrier strip.
(3)  Observe electronic voltmeter and slowly turn
transformer case to minimize indication on electronic
(4)  Connect electronic voltmeter to terminals E
voltmeter.
and F of barrier strip with test leads.
(4)  Tighten the three clamp screws that secure
(5)  Unlock NAVIGATION GROUND SPEED dial
case of transformer B1.
lock. Then energize 115 vac, 400 Hz primary power
circuit.
10.
Navigation  Drift  Transformer
B2
Coarse
Position. a. Performance Check.
(6)
Observe electronic voltmeter and carefully turn
NAVIGATION GROUND SPEED dial to minimize
indication
on
electronic
voltmeter.
6