| ||||||||||
|
|
![]() ![]() TM 11-6625-3056-12
2-5.
SELF-TEST (cont)
5.
Long
·
Set controls as follows:
Pattern
Correlator
PATTERN
LONG
Loop
OPERATION
Keep at 4W
CORRELATOR LOOP
OPEN
DATA ON/OFF
Keep at ON
RATE SELECT
Keep at 7 (32 kb/s)
DISPLAY SELECT
Keep at ERRORS
Keep DATA OUT connected to DATA IN.
·
Press RESET:
Display must read 0.
If display does not stay at 0 and increases count rapidly, polarity
of DATA OUT and/or DATA IN connections may be wrong. Reconnect with opposite
polarity and repeat test.
·
Press SINGLE ERROR several times:
Display must advance one count each time SINGLE ERROR is pressed.
·
Set CORRELATOR LOOP to CLOSED and press RESET:
Display must read 0.
·
Press SINGLE ERROR several times:
Display must advance one count each time SINGLE ERROR is pressed.
2-8
|
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |