Click here to make tpub.com your Home Page

Page Title: TABLE NO. 3-23. Multimeter Does Not Indicate 1.0 6 0.2 Vdc With LATL ACCLRM Switch Place To SIM STAB 1, SIM STAB 1&2, And SIM...
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
TABLE NO. 3-21. Multimeter Does Not Indicate -0.69 6 0.08 Vdc With PITCH RATE GYRO Switch Set To SIM SAS (WO)
Up
TM-1-6625-735-14 Test Set Stabilization System P/N 70700-20650-050 Manual
Next
TABLE NO. 3-25. INDICATORS NO. 1 SLEW UP And NO. 1 HOT SLEW Do Not Go On When MANUAL SLEW 1 Switch Is Pressed And Held At UP.

TM 1-6625-735-14
TABLE NO. 3-23. Multimeter Does Not Indicate 1.0 6 0.2 Vdc With LATL ACCLRM Switch Place To
SIM STAB 1, SIM STAB 1&2, And SIM STAB 2. (Cont)
TEST OR INSPECTION
CORRECTIVE ACTION
2. Place LATL ACCLRM control to SIM STAB 1. Multimeter shall indicate 1.06 0.2
vdc.
Step 1. If multimeter indication is not correct, replace switch S15.
Step 2. If multimeter indication is correct, go to 3.
3. Connect multimeter between LATL ACCLRM SIM STAB 2 and SIG GND test
jacks. Go to 4.
4. Place PITCH RATE GYRO control to SIM STAB 1&2 and then to SIM STAB 2.
Multimeter shall indicate 1.0 6 0.2 vdc in each position. Go to 5.
5. If multimeter indication is not correct, replace switch S15.
TABLE NO. 3-24. Multimeter Does Not Indicate -3.05 6 0.33 Vdc When LATL ACCLRM Switch Is
Placed To SIM SAS 1.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Connect multimeter between LATL ACCLRM SIM SAS and SIG GND test jacks.
Go to 2.
2. Place LATL ACCLRM control to SIM SAS 1. Go to 3.
3. Turn LATL ACCLRM control throughout its range from fully counterclockwise (L)
to fully clockwise (R). Multimeter shall indicate -3.056 0.33 when LATL ACCLRM
control is fully counterclockwise and shall indicate 3.05 6 0.33 when LATL ACCLRM
control is fully clockwise. Digital multimeter shall indicate a continuously adjustable
voltage from counterclockwise to clockwise position.
Step 1. If multimeter indicates 0.0 vdc, go to 4.
Step 2. If multimeter indication changes abruptly from -3.38 to 3.38 vdc, replace
potentiometer R6.
4. Check switch S15 for continuity.
Step 1. If continuity exists, replace circuit board assembly A2.
Step 2. If continuity does not exist, replace switch S15.
3-23

Privacy Statement - Press Release - Copyright Information. - Contact Us