Back 4-25. REMOVE AND REPLACE METERING VALVES (TYPICAL) | Up TM-1-4920-458-13P Tester Pitot and Static System P/N 3400-0003 Manual | Next 4-26. REMOVE AND REPLACE TOGGLE SWITCH . |
TM 1-4920-458-13&P
4-25.
REMOVE AND REPLACE METERING VALVES (TYPICAL) (Cont)
(Sheet 2 of 2)
4-25.1. REMOVAL
a.
Disconnect hose (1) from fitting (2) and rigid pipe (3) from fitting (4).
b.
Remove panel mounting nuts (5 and 6) and remove metering valves (7 and 8) from control panel (9).
c.
Remove fittings (2 and 4) from metering valves (7 and 8).
4-25.2. INSTALLATION
a.
Apply Sealube (D6) to fittings (2 and 4).
b.
Install fittings (2 and 4) to metering valves (7 and 8).
c.
Place metering valves in holes in control panel (9) and secure with panel mounting nuts (5 and 6).
d.
Attach hose (1) to fitting (2) and rigid pipe (3) to fitting (4).
4-25.3. FOLLOW ON MAINTENANCE
Performance check (para. 2-5)
END OF TASK
4-27
|