Click Here to
Order this information in Print

Click Here to
Order this information on CD-ROM

Click Here to
Download this information in PDF Format

 

Click here to make tpub.com your Home Page

Page Title: Answers
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   
Back
Example 2
Up
Engineering Symbology Prints and Drawings Volume 2 of 2
Next
Answers

TRUTH TABLES AND EXERCISES DOE-HDBK-1016/2-93 Logic Diagrams PR-05 Page 18 Rev. 0 Answers to example 1. 1. a.  2 b.  3 c.  1 d.  4 2. The  safety  signal  must  be  received  for  greater  than  10  minutes  before  it  will  pass through the time delay.  If the safety signal is removed before 10 minutes has elapsed no signal will be passed to Gate 2. 3. Gate 2 will turn on when the hand-switch is in the AUTO position and a safety signal has been received for greater than 10 minutes. 4. If flow switch (FS) 30-38 senses less than 20,000 cfm, 45 seconds after the fan has started, or the same condition exists on the 1B-B fan, the alarm will sound. 5. AND Gate 2 prevents the on signal from passing until a safety signal is also received (>10 minutes). 6. Ten minutes after receiving the safety signal, the fan started.  At 12 minutes, removing the  safety  signal  only  removes  the  continuous  start  signal  to  the  fan.    The  fan  will continue to run until the hand switch is placed in the stop position.  Further, with the removal of the safety signal, the fan will remain stopped when the hand switch spring returns  to  the  AUTO  position.    Note  that  if  the  hand  switch  is  placed  in  the  stop position while the safety signal is present, the fan will stop, but will restart as soon as the switch spring returns to the AUTO position. 7. It can be started by two signals - START and AUTO plus a safety signal. It can be stopped by one signal - STOP (but will only remain stopped if no safety signal is present or the switch is held in the stopped position). Answers to example number 2. 1. a.  1 & 4 b.  2 c.  3 2. Right input is - on - this is because the hand control switch is in the AUTO position, and the AUTO switch contacts are made up, resulting in an on signal.  Therefore the hand- switch CLOSE position contacts are open, resulting in an off signal.  The off signal is reversed in the NOT gate and becomes an on signal.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing