Figure 5   Strain Gauge Used in a Bridge Circuit

Pressure Detectors PRESSURE DETECTION CIRCUITRY Figure 3 Strain Gauge As the wire grid is distorted by elastic deformation, its length is increased, and its cross-sectional area decreases.  These changes cause an increase in the resistance of the wire of the strain gauge. This change in resistance is used as the variable resistance in a bridge circuit that provides an electrical signal for indication of pressure.  Figure 4 illustrates a strain gauge pressure transducer. Figure 4    Strain Gauge Pressure Transducer Rev. 0 Page 7 IC-02