Minor Losses
Up
Thermodynamics Heat Transfer and Fluid Flow Volume 3 of 3
Next
Head Loss Summary

Fluid Flow HEAD LOSS TABLE 1 Typical Values ofLeq D Item Leq D Globe Valve Conventional Y-Pattern Gate Valve Fully Open 75% Open 50% Open 25% Open Standard Tee Flow through Run Flow through Branch 90° Standard Elbow 45° Standard Elbow Return Bend 400 160 10 35 150 900 10 60 30 16 50 Example: A fully-open gate valve is in a pipe with a diameter of 10 inches.  What equivalent length of pipe would cause the same head loss as the gate valve? Solution: From Table 1, we find that the value of Leq/D for a fully-open gate valve is 10. Leq =    (L/D) D =    10 (10 inches) =    100 inches By adding the equivalent lengths of all components to the actual length of pipe in a system we can obtain the Leq value for the entire piping system. Rev. 0 Page 35 HT-03