Figure 15    Three-Phase To Single-Phase Connections
Up
Electrical Science Volume 4 of 4
Next
4-Wire, Three-Phase Delta System

WIRING SCHEMES AND GROUNDING Electrical Distribution Systems Figure 16    3-Wire Edison Scheme The physical connections to the transformer secondary involve two insulated conductors and one bare conductor.   If the conductor is a current-carrying leg or neutral leg, the conductor will be insulated.  The remaining uninsulated conductor will serve as a safety ground and will be bonded to the ground point of the system.   In all cases, 3 wires will be presented to the load terminals, and the safety ground will be bonded to each junction box, or device, in the distribution system. In the case of half voltage (120 V) use, the intended path of the current is from the supply leg through the load and back to the source on the neutral leg.   No current would be carried on the ground  unless  a  fault  occurred  in  the  system,  in  which  case  the  current  would  flow  safely  to ground. In the full voltage system (240 V), the insulated conductors are connected across the full winding of  the  transformer,  and  the  uninsulated  conductor  is  again  bonded  to  the  grounded  center  tap. In a balanced system, all currents will flow on the insulated conductors, and the grounded neutral will carry no current, acting only in a ground capacity.  In the case of either an unbalanced load or a fault in the system, the bare conductor will carry current, but the potential will remain at zero volts because it is tied to the ground point.   As in the case of the half voltage system, the uninsulated conductor will be bonded to each device in the system for safety. Three-Phase Wiring Schemes Unlike the single-phase wiring scheme that must make a provision for a neutral leg and separate ground, the three-phase system needs neither a separate neutral nor a ground to operate safely. However, to prevent any unsafe condition, all 3- and 4-wire, three-phase systems can include an effective ground path.   As with the previous single-phase discussion, only the secondary side of the transformer and its connected load need to be studied. 3-Wire, Three-Phase Delta System The simplest three-phase system is the 3-wire Delta configuration, normally used for transmission of power in the intermediate voltage class from approximately 15,000 volts to 600 volts.   The diagram in Figure 17 depicts the two methods of connecting the Delta secondary. ES-15 Page 24 Rev. 0