Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: OPERATION PROCEDURES (OP) FOR DIVING OPERATIONS 2 -cont
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home




   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
OPERATION PROCEDURES (OP) FOR DIVING OPERATIONS 2
Up
TM-5-4220-231-14P Recompression Chamber 3-Person Model RC-100-2 Serial Numbers 08-A-163 Thru 08-A-172 Manual
Next
OPERATION PROCEDURES (OP) FOR DIVING OPERATIONS 2 -cont



TM5-4220-231-14&P OPERATION PROCEDURES  (OP) FOR DIVINGOPERATIONS OPERATOR CHECKLISTOP 2 -  (Cont.) DATE START    TIME END   TIME OPERATOR1 OPERATOR 2 LOCATION STEP ITEM LOCATION ACTION PERFORMED CHECKED Y -[BY BY ENABLE   SECONDARY DASS    OP   2.3 2.3.1 AHP-V205 DASS     Rack Fully   open    CCW    - Turn   back    1/4   CW. 2.3.2 AHP-V201 DASS    Rack    - Slowly    open     fully   CCW    - Front    - Turn   Back    1/4   CW. AHP-V202 Flask    Valves AHP-V206 Rear    - Slowly    open    fully   CCW    - AHP-V207 Flask    Valves Turn    Back    1/4   CW. 2.3.3 AHP-V209 DASS     Rack Slowly    open    CCW    - Turn    back    1/4   CW   - Release pressure to   DACC Primary HP   IN. 2.3.4 AHP-G211 DASS     Rack Record Pressure: PSIG. ENABLE    THE   SDASS OP   2.4 2.4.1 ALP-V509 VTA   Control Open     CCW    - Panel Arrow   points     open. 2.4.2 AHP-V403 DACC    Control Open     CCW    - Panel    - Arrow    points     open. Secondary 2.4.3 ALP-V404 DACC    Control Open     CCW    - Panel     - Arrow    points     open. Secondary 2.4.4 ALP-V414 DACC    Control Open     CCW    - Panel     -   Center Arrow    points     open. 2.4.5 AHP-V401 DACC    Control Slowly    open     CCW    - Panel     - Arrow    points     open. Secondary 2.4.6 AHP-G421 DACC    Control Read     and    record pressure: Panel    - should     be   the   same as Secondary secondary DASS AHP-G211. Pressure PSIG. NOTE Supervisor: Calculate air  requirements for  planned diving    operations. o a s If sec ndary DASS r   ck   pressure is  not ufficient, complete OP   10   at  this   time. 2.4.7 AHP-V402 DACC Control Adjust    to   desired over    bottom Panel - pressure. Record pressure Secondary from    ALP-G422. Pressure PSIG. Change 6 2-49



Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing