Table  2-2  Control  Cabinet  Assembly  Description  of  Circuit  Breakers
Up
TM-9-6115-668-13 5Kw 28VDC Auxiliary Power Unit (APU) MEP 952B Manual
Next
Figure 2-4 Base Frame Assembly, J3 SLAVE RECEPTACLE 24 VOLTS

TM   9-6115-668-13 2.1.3 Receptacles. Control  cabinet  assembly  receptaclesare  illustrared  in  figure  2-3.  Receptacle  functions  are  described  in  table  2-3.  J3 SLAVE  RECEPTACLE  24  VOLTS  on  the  base  frame  assembly  is  illustrated  in  figure  24. ltem Number 1. L1  (ØA)  receptacle  with  locking  switch 2. L2  (ØB)  receptacle  with  locking  switch 3. L3  (ØC)  receptacle  with  locking  switch 4. N  receptacle  with  locking  switch 5. J9  PARALLEL  OPERATION  receptacle 6. J1/120  V  400  Hz  double  receptacle 7. J2/24  V  receptacle 8. WARNING  plate 9. WARNING  plate Figure  2-3  Control  Cabinet  Assembly,  Receptacles. Table  2-3  Control  Cabinet  Assembly,  Description  of  Receptacles. Description Function Connection  to  EPP  Ill,  PDU  power  cable Connection  to  EPP  Ill,  PDU  power  cable Connection  to  EPP  Ill,  PDU  power  cable Connection  to  EPP  Ill,  PDU  power  cable Connection  to  EPP  Ill,  PDU  power  cable Load  connection  (maximum  16  A) Load  connection  (maximum  6  A) WARNING 208 VAC WARNING  208  VAC  -  Install  Protective  Covers 2-10 Change   1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing