Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Table 2-1 Control Cabinet Assembly, Description of Controls and Indicators.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Section  I.  DESCRIPTION  AND  USE  OF  CONTROLS  AND  INDICATORS
Up
TM-9-6115-668-13 5Kw 28VDC Auxiliary Power Unit (APU) MEP 952B Manual
Next
Control  Cabinet  Assembly,  Description  of  Controls  and  Indicators  (continued).

TM    9-6115-668-13 Table  2-1   Control Cabinet Assembly, Description of Controls and Indicators. Item Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Function AMPS L1 (OA) meter 0 - 600 A (P1) Indicates current in line 1 UNDER/OVER  FREQUENCY  illuminated H8 lights up if generator frequency is above or pushbutton switch, red (H8, S4) below setpoint; S4 cancels the fault message AMPS L2 (OB) meter 0 - 600 A (P2) Indicates current in line 2 UNDER/OVER VOLTAGE illuminated H9 lights up if generator voltage is above or pushbutton switch, red (H9, S5) below setpoint; S5 cancels the fault message GENERATOR OVER TEMPERATURE illu- H10 lights up if generator overheats; S6 cancels minated pushbutton switch, red (H10, S6) the fault message AMPS L3 (OC) meter 0 - 600 A (P3) Indicates current in line 3 OVERLOAD  illuminated  pushbutton  switch, H13 lights up if generator overloads; S10 cancels red (H13, S10) the fault message REVERSE POWER illuminated pushbutton H11 lights up if reverse power is too high; S22 switch, red (H11, S22) cancels the fault message Lights (H6) For front panel illumination; use PANEL DIMMER switch/potentiometer (33) to turn on and adjust brightness BATTERY CHARGING CONTROL lamp, Must go out after start; if H2 lights up during red  (H2) operation, battery set is not being charged VOLTAGE meter 0 - 250 V (P6) Indicates line or phase voltages L-L or L-N OIL PRESSURE lamp, red (H3) Must go out after start; if H3 lights up during operation, oil pressure is too low OIL  TEMP-CYLINDER  HEAD  lamp,  red Lights up when oil and/or cylinder head (H4) temperature is too high FREQUENCY meter, digital display (P5) Displays generator frequency (400.0 ± 0.2 Hz during operation) 2 - 3

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing