TM-9-6115-659-13P Power Unit PU-732/M (NSN 6115-00-280-3082) MEP-118A 15 Kw 400 Hz Generator Set M200A1 2-Wheel 4-Tire Modified Trailer Manual
Next
Figure 3-1.  ON Indicator Lamp Falls to Light With Generator Set Running.

TM 9-6115-659-13&P Section II.  TROUBLESHOOTING 3-2 TROUBLESHOOTING. 3-2.1 Generator Set.  Refer to TM 9-6115-641-10. 3-2.2 Trailer.    Refer  to  TM  9-2330-202-14&P  for  Power  Plant  AN/MJQ-35  and  Power  Unit  PU-797,  TM  9-2330-392- 14&P for Power Plant AN/MJQ-35A and Power Unit PU-797A, and TM 9-2330-213-14&P for Power Plant AN/MJQ-36. 3-2.3 Power Plant.    The  following  symptom  index  lists  faults  associated  with  switch  box  operation.    Figures  3-1,  3-2, and 3-3 provide a go/no-go flowchart of each malfunction.  Each malfunction listed includes a reference to the applicable figure  that  contains  a  chart  that  will  help  you  determine  probable  causes  and  corrective  actions  to  take.    The  symptom index cannot list all faults that may occur, nor all tests or inspections and corrective actions.  If a malfunction is not listed or cannot be corrected by listed corrective actions, notify next higher level of maintenance. SYMPTOM INDES Troubleshooting (Figure) ON INDICATOR LAMP FAILS TO LIGHT WITH GENERATOR SET RUNNING  .......................................... 3-1 ON-LINE INDICATOR LAMP FAILS TO LIGHT WHEN ON/OFF SWITCH IS PLACED IN ON POSITION ........................................................................................................................ 3-2 SYNCHRONIZING INDICATOR LAMPS FAIL TO LIGHT WHEN TRANSFER SWITCH IS OPERATED  ............................................................................................................ 3-3 WITH ALL INDICATOR LAMPS WORKING PROPERLY, LOAD WILL NOT TRANSFER ................................................................................................................................... 3-4 SYNCHRONIZING INDICATOR LAMPS FAIL TO OPERATE IN UNISON WHEN TRANSFER SWITCH IS OPERATED  ................................................................................................ 3-5 Change 2  3-3