Back Figure 2-8. Power Plant and Power Unit Ground Connections | Up TM-9-6115-659-13P Power Unit PU-732/M (NSN 6115-00-280-3082) MEP-118A 15 Kw 400 Hz Generator Set M200A1 2-Wheel 4-Tire Modified Trailer Manual | Next 2-5.3.1 Operating a Single Generator Set |
TM 9-6115-659-13&P
WARNING
Make sure generator sets are shut down before connecting load cables. Failure to
observe this WARNING can cause severe personal injury or death.
2-3.4.1.1
Connection to Output Connector.
a.
Remove cap (6, figure 2-9) from output connector (7).
b.
Connect load cable to output connector (7).
WARNING
Make sure generator sets are shut down before connecting load cables. Failure to
observe this WARNING can cause severe personal injury or death.
2-3.4.1.2
Connection to Switch Box Load Terminals.
a.
Release both clamping catches (4, figure 2-9) and raise load terminal cover (2).
Figure 2-9. Switch Box Load Cable Connections.
b.
Select required output terminals from table 2-3.
Change 2 2-35
|