2-2.4.3  Routine Inspections
Up
TM-9-6115-659-13P Power Unit PU-732/M (NSN 6115-00-280-3082) MEP-118A 15 Kw 400 Hz Generator Set M200A1 2-Wheel 4-Tire Modified Trailer Manual
Next
Figure  2-2.  AN/MJQ-35  Power  Plant  Operator  PMCS  Routing  Diagram

TM 9-6115-659-13&P Class III Leakage of fluid great enough to form drops that fall from the item being checked/inspected. 2-2.6  Operation of Power Plant/Power Unit with Minor Leaks. CAUTION Equipment operation is allowable with minor leakage (Class I or II) of any fluid except fuel. Fluid capacity must be considered before deciding to continue operation of the equipment with  minor  leaks.    When  operating  with  Class  I  or  II  leaks,  fluid  level  must  be  checked more often than required by the PMCS table.  Parts without fluid will stop working and/or cause equipment damage. a. Consider  the  equipment’s  capacity  for  the  fluid  that  is  leaking.    If  the  capacity  is  small,  the  fluid  level  may  soon become too low for continued operation.  If in doubt, notify your supervisor. b. Check the fluid level more often than required in the PMCS table.  Add fluid as needed. 2-2.7  Corrosion Prevention and Control (CPC).  CPC of Army materiel is of continuing concern.  It is important that any corrosion problems with the power plant or power unit be reported so that the problem can be corrected and improvements can be made to prevent the problem in future items.  While corrosion is typically associated with rusting of metals, it can also include deterioration of other materials, such as rubber and plastic.  Unusual cracking, softening, swelling, or breaking of  these  materials  may  be  a  corrosion  problem.    If  a  corrosion  problem  is  identified,  it  can  be  reported  using  Standard Form 368,  Product Quality Deficiency Report.  Use of key words such as "corrosion, " "rust, " "deterioration, " or "cracking" will ensure that the information is identified as a CPC problem.  The form should be submitted to the address specified in DA Pam 738-750. 2-2.8  Order in Which PMCS Will be Done.  Figures 2-2, 2-3, 2-3.1, 2-3.2, and 2-4 show the order in which you are to perform your before operation PMCS .  Figure 2-2 is for the AN/MJQ-35, figure 2-3 is for the AN/MJQ-36, figure 2-3.1 is for the AN/MJQ-35A, figure 2-3.2  is  for  the  PU-797A,  and  figure  2-4  is  for  the  PU-797.    The  number  callouts  on  all  figures correspond to the numbers in the Item No.  column of table 2-2.  Callouts on figures 2-2,  2-3,  and  2-3.1  for  one  Power Plant generator set apply to both of the Power Plant generator sets. 2-6  Change 2