2-3.2.2  External Fuel Line Connection.
Up
TM-9-6115-658-13P Power Unit PU707A/M (NSN 6115-00-394-9573) MEP-115A 60 Kw 400 Hz Generator Set M200A1 2-Wheel 4-Tire Modified Trailer Manual
Next
Figure 2-5.  Ground Rod and Slide Hammer.

TM 9-6115-658-13&P 2-23 b.    Remove the container adapter (3) from the accessory storage box.  If disassembled, remove all components.  The components are the assembled clamp and head (5 and 6), a fuel pickup tube (7), and an extension pipe (8).  The extension pipe (8) is not needed if the external fuel source is a 5-gallon fuel can (2). NOTE Make sure that all components are clean. c.    Thread the fuel pickup tube (7) into the head (6).  If the external fuel source is a 55-gallon container, thread the extension pipe (8) onto the fuel pickup tube (7). d.    Remove the auxiliary fuel hose (4) from its storage location.  It is stored in a compartment below the generator set control panel, behind the bottom-right access door. e.    Thread one end of the auxiliary fuel hose (4) onto the fitting on the container adapter (3). Tighten the connection. f. Connect the free end of the auxiliary fuel hose (4) onto the generator set external fuel supply elbow connection (1).  The connection is located beside the generator set fuel tank filler neck.  Tighten the connection. The fuels used in this generator set are flammable.  Do not smoke or use open flames when performing maintenance.  Flames and explosion could result in severe personal injury or death. g.    Insert the container adapter (3) into the external fuel source (2).  Secure the container adapter by pressing down on the handle of the clamp (5). Never attempt to start the generator set if it is not properly grounded. Failure to observe this warning could result in severe personal injury or death by electrocution. 2-3.3 Grounding of Generator Set.  Ground the equipment in accordance with Army Field Manual FM 5-424.  Typical ground rod installations are shown in Figure 2-5.  If a ground rod is used, install and connect it as follows: a.    Remove ground rod (7), grounding strap (8), an slide hammer (5) , (Figure 2-5) from accessory box   (Figure 1-2). b.   Perform assembly steps as follow on the next page (1) through (4). WARNING WARNING