TM 9-6115-658-13&P
2-13
Table 2-2. Operator Preventive Maintenance Checks and Services (continued)
ITEM
NO.
INTERVAL
LOCATION
PROCEDURE
NOT FULLY
MISSION
CAPABLE IF:
ITEM TO
CHECK/SERVICE
7
Before
DRAWBAR RING
Check drawbar ring (11) for secure mounting
and obvious damage.
Ring is loose or
bent.
8
Before
INTERVEHICULAR
CABLE
a. Check intervehicular cable (12) for cuts
and breaks.
b. Open protective cover (13). Inspect for
broken, missing, and burnt pins (14).
Cable is severed or
missing.
9
Before
SAFETY CHAINS
Check safety chains (15) for secure mounting
and obvious damage.
Chain is missing or
unsecured.
|