Page Title: Table 2-3. Annunciator Control Panel A, Controls and Instruments
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 2-3.  Annunciator Control Panel A, Controls and Instruments
Up
TM-9-6115-604-12 Generator Set Diesel Engine Driven Tactical Skid Rtd. 60 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Figure 2-4.  Annunciator Panel A9 Indicators

ARMY TM 9-6115-604-12 NAVY NAVFC P-8-633-12 Table 2-3.  Annunciator Control Panel A, Controls and Instruments Figure 2-3, 1 CLOCK 60 HZ Ml 110 To indicate time -- Figure 2-3, 2 ANNUNCIATOR RESET push- Used to clear annunciator panel A9 after -- button S12 an alarm condition has been corrected. Figure 2-3, 3 ALARM SILENCE pushbutton Used to shut down horn LS1 and stop -- S16 flasher DS19 after an alarm circuit trips. Figure 2-3, 4 Annunciator Panel A9 In the event of an alarm condition, this Dark back-lit panel will light to show which one of 14 possible alarm conditions caused the alarm.  See figure 2-4 Figure 2-3, 5 ANNUNCIATOR TEST pushbut-   Used to test annunciator panel A9 and -- ton S15 horn LS1 Horn will sound and all lights in annunciator panel will light when but- ton is pressed. Figure 2-3, 6 CLOCK 50 HZ M111 To indicate time. -- Figure 2-3, 7 KILOWATT HOURS counter Indicates total accumulated kilowatt- -- CNTR hour output of the generator set Figure 2-3, 8 FREQUENCY SEL SW S118 To set the generator set for 50 or 60 Hz -- operation. Figure 2-3, 9 CROSS CURRENT ADJUST Used when paralleling to prevent recir- -- Rheostat R105 culating currents between generator sets Figure 2-3, 10 Over current Relay K114 Used to trip open load circuit breaker in -- event of overload current or short circuit. See figure 2-5. Figure 2-3, 11 GROUND FAULT Relay K 115 Used to trip open load circuit breaker -- CB101 in event of current flow in neu- tral. FIGURE AND INDEX NO. CONTROL OR INSTRUMENT FUNCTION NORMAL READING/ SETTING AT RATED LOAD 2-9