Figure 2-2.  Generator Control Panel B, Controls and Instruments
Up
TM-9-6115-604-12 Generator Set Diesel Engine Driven Tactical Skid Rtd. 60 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
oTable 2-2.  Generator Control Panel B, Controls and Instruments (Continued)

ARMY TM 9-6115-604-12 NAVY NAVFC P-8-633-12 Table 2-2.  Generator Control Panel B, Controls and Instruments (Continued) Figure 2-2, 5 SYNCHROSCOPE M106 Used with SYNCHRONIZING LIGHTS -- DS110 and DS111 when paralleling. When the SYNCHROSCOPE pointer is at the 12 o'clock position, DS110 and DS111 will be dark.  Shows phase rela- tionship between on-line and incoming units. Figure 2-2, 6 AC KILOWATTS meter M107 Indicates kilowatt output of generator 50 Hz - 625 set. 60 Hz - 750 Figure 2-2, 7 AC KILOVARS meter M108 Indicates kilovar output of generator set. 50 Hz - 469 60 Hz - 562 Figure 2-2, 8 FREQ ADJ rheostat R102 Provides adjustments of generator set -- frequency In single set operation or load in parallel operation Figure 2-2, 9 POWER FACTOR meter M104 Indicates power factor of generator set 50 Hz - 0.8 output.  LAG Indicates an Inductive load. 60 Hz - 0.8 LEAD indicates a capacitive load. Figure 2-2, 10 GEN TEMP meter M105 Indicates temperature of generator G1 Normal ambient windings at selected points to 150° F (66° C) Figure 2-2, 11 SYNCHROSCOPE switch S115.  Used to turn SYNCHROSCOPE M106 OFF. ON or OFF. Figure 2-2, 12 FREQUENCY DROOP/ ISO- Used to select ISOCHRONOUS or CHRONOUS switch S117 FREQUENCY DROOP paralleling Figure 2-2, 13 TEMPERATURE INDICATOR Used with GEN TEMP meter M105 to -- switch S113 read generator G1 temperature at one of the six equally spaced points around the stator. Figure 2-2, 14 Phase sequence lights (1-2-3, Used with PHASE SEQ SEL.  SW S119 Dark 3-2-1) DS112 and DS113 to compare generator and bus phase sequence. Figure 2-2, 15 PHASE SEQ.  SEL.  SW S119 When set to GEN or BUS, indicates Both GEN and whether phase is 1-2-3 or 3-2-1. BUS should indi- cate same phase sequence. Figure 2-2, 16 PHASE SEQ LAMP TEST Used to test phase sequence lights When button is pushbutton S116 DS112 and DS113. pressed, DS112 and DS113 should light. Figure 2-2, 17 PARALLEL Indicator DS35 and   Indicates setting of PARALLEL Switch SINGLE SET indicator DS36 S6. Figure 2-2, 18 PARALLEL switch S6 Used to select PARALLEL or SINGLE set operation. Figure 2-2, 19 OPEN indicator DS33 and Indicates whether load circuit breaker CLOSED indi- CLOSED indicator DS34 CB101 Is OPEN or CLOSED. cator DS34 lit, OPEN indicator DS33 dark. FIGURE AND INDEX NO. CONTROL OR INSTRUMENT FUNCTION NORMAL READING/ SETTING AT RATED LOAD 2-6