Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Table 1-1. System Capacities and Detailed Data on Components (Continued)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Table 1-1. System Capacities and Detailed Data on Components (Continued)
Up
TM-9-6115-604-12 Generator Set Diesel Engine Driven Tactical Skid Rtd. 60 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Table 1-1. System Capacities and Detailed Data on Components (Continued)

ARMY TM 9-6115-0412 NAVY NAVFAC P-8-633-12 Table 1-1. System Capacities and Detailed Data on Components (Continued) 9. CONTROLS, INSTRUMENTS, AND SWITCHGEAR (CONTINUED) Radiant Heaters HR103 and HR104 Drawing Number. 80-7619 Rating 240 V ac, 1250 watts, UL listed Operating Temperature. -25 to +125°F (-31 to 51°C) Storage Temperature. -65 to +155°F (-53 to 68°C) Humidity Conditions. To 100% Manufacturer: Electromagnet Industries Part Number: NBRA 2412 FSCM: 12670 Paralleling Current Transformer CT114 Drawing Number 80-7403 Specification ANSI C57.13 Accuracy Class. 0 6-B0-2 Current Ratio: 130/5 amperes Burden. 5 V a minimum Operating Temperature: -25 to +125°F (-31 to 51 °C) Storage Temperature -65 to +155°F (-53 to 68°C) Humidity Conditions To 100% Manufacturer Instrument Transformer Company Part Number 100-131 FSCM. 59138 Instrument Current Transformers CT10 through CT12 Drawing Number 80-7409 Specification ANSI C57.13 Accuracy Class 0.6 B0.9 Burden 22.5 V a minimum Operating Temperature. -25 to +125°F (-31 to 51°C) Storage Temperature: -65 to +155°F (-53 to 68°C) Humidity Conditions. To 100% Current Ratio 175/5 amperes Manufacturer Instrument Transformer Company Part Number 112-1750 FSCM. 59138 Ground Fault Transformer T100 Drawing Number 80-7437 Rating Single phase, 50/60 Hz, 1 kVa, 4160/230 volts Low Voltage Cables: No 14 AWG to terminal block High Voltage Cables: No. 14 AWG (5 kV insulation), 20 00 long Operating Temperature -25 to +125°F (-31 to 51 °C) Storage Temperature -65 to +155°F (-53 to 68°C) Humidity Conditions: To 100% Manufacturer General Electric Company Part Number 9T28B9710G10 FSCM: 03512 145

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing