Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: SECTION II. DESCRIPTION AND DATA
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
CHAPTER 1 INTRODUCTION
Up
TM-9-6115-604-12 Generator Set Diesel Engine Driven Tactical Skid Rtd. 60 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Figure 1-1.  Generator Set - Front Three-Quarter View

ARMY TM 9-6115-604-12 NAVY NAVFAC P-8-633-12 SECTION II.  DESCRIPTION AND DATA 1-9. DESCRIPTION. a. General.  The generator set (see Figure 1-1 through Figure 1-8) Is an enclosed, diesel engine-driven, prime utility  (Type  II)  unit,  producing  750  kW,  at  60  Hertz  (Hz),  625  kW  at  50  Hz,  0  8  power  factor  (pf),  lagging,  with  the following output voltages: (1) For 60 Hz operation.  2400/4160 volts, 3 phase, 4 wire, wye (2400 volts line-to-neutral,  4160  volts  line-to- line). (2) For 50 Hz operation.  2200/3800 volts, 3 phase, 4 wire, wye (2200 volts line-to-neutral, 3800 volts line-to- line). b. Engine.  The engine Is liquid-cooled, 12 cylinder, 2300 cubic inch (37 7 liters) displacement, four-stroke cycle diesel, turbocharged, and aftercooled. c. Generator.    The  generator  is  a  brushless,  rotating  exciter,  single  bearing,  air-cooled,  open-drip-proof  unit. The generator is directly connected to the engine and delivers 50 Hz, 781 3 kVa at 0 8 power factor at 1500 revolutions per minute (rpm) or 60 Hz, 937.5 kVa at 0 8 power factor at 1800 rpm.  The generator is wye connected. d. Housing.  The housing is a weathertight, removable enclosure, bolted to a skid-base.  Doors enable access to major components for service or maintenance Air intake an exhaust opening allow set operation with all doors closed. A permanently installed ladder allows access to the roof of the generator set.  The roof will support a 200 pound (91 kg) person.      Fixed   partitions   within   the   housing   divide   the   generator   set   Into   an   engine   compartment,   switchgear compartments (cabinets), and weathertight control compartments (control room). e. Control Room.  The control room has 24 square feet (2.2 square meters) of floor space and Is equipped with lights, exhaust fan, space heaters, and a small desk.  Generator controls, on two panels, and engine controls, on a third panel, enable operation of the generator set from the control room. f. Remote  Control.    Module  (RCM)  See  Figure  1-9.    The  remote  control  module  (RCM)  is  available  as  an auxiliary unit used In conjunction with the generator set.  It allows remote start, stop, monitor, and control of a generator set in single operation or in parallel operation with the like sets from a remote location of up to 100 feet (30 m) away. Details on the operation and maintenance of the RCM are contained in Chapter 5 of this manual. 1-2

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing