Table 2-2. TROUBLESHOOTING (CONTINUED)
Up
TM-9-6115-464-34 Generator Set Diesel Engine Driven Tactical Skid Mtd 15 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
ENGINE KNOCKS

ARMY   TM   9-6115-464-34 AIR  FORCE  TO  35C2-3-445-2 NAVY  NAVFAC  P-8-624-34 Table 2-2. TROUBLESHOOTING (CONTINUED) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION Step 7. Defective hydraulic pump (Electro-hydraulic governor equipped precise sets only) (figure 3-34). Test and repair hydraulic pump (para. 3-41). Step 8. Defective cylinder head gasket (11, figure 3-46). Replace defective cylinder head gasket (para. 3-54). Step 9. Improper governor adjustment. Adjust governor (para. 3-64, Electro-hydraulic governor, or 3-65, electric governor equipped precise sets). 7. ENGINE WILL NOT IDLE SMOOTHLY. Step 1. Burned or sticking valves (26 and 27, figure 3-46). Repair or replace valves (para. 3-54). Step 2. Weak or broken valve springs (24 and 25, figure 3-46). Replace valve springs (para. 3-54). Step 3. Fuel injection nozzles out of adjustment, dirty or defective (figure 3-25). Clean, adjust or replace fuel injection nozzles (para. 3-23). Step 4. Defective camshaft (figure 3-50). Replace camshaft (para. 3-55). Step 5. Fuel injection pump defective or out of time (figure 3-21). Adjust, repair, or replace fuel injection pump (para. 3-22). 8. ENGINE OVERHEATS. Step 1. Defective shutter control or linkage (figure 3-26). Replace shutter control linkage (para. 3-30). Step 2. Defective water pump assembly (figure 3-28). Repair or replace water pump assembly (para. 3-32). Step 3. Clogged or defective radiator. Clean, repair or replace radiator (para. 3-29). 2-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing