APPLICATIONS KIT.

ARMY  TM  9-6115-464-12 AIR FORCE TO 35C2-3-445-1 NAVY NAVFAC P-8-624-12 Step  1. Step  2. Step  3. Step  4. Step  5. Step 6. Step  7. 2-30 ALWAYS CHECK THE POSITION OF THE GENERATOR SET VOLTAGE RE- CONNECTION  BOARD  BEFORE  PLACING  THE  LOAD  BANK  IN  OPERA- TION. DAMAGE TO THE LOAD BANK WILL RESULT IF IT IS OPERATED AT A VOLTAGE DIFFERENT FROM THE GENERATOR SET OUTPUT VOLTAGE. EQUIPMENT DAMAGE COULD RESULT IF CAUTION IS NOT OBSERVED. CONNECT THE VOLTAGE SELECTOR WIRING HARNESS TO THE VOLTAGE SELECTOR CON- NECTOR CORRESPONDING TO THE GENERATOR SET OPERATING VOLTAGE. INSTALL THE PROTECTIVE CAP OVER THE REMAINING CONNECTOR. DO NOT ALLOW THE GENERATOR SET TO OPERATE UNATTENDED WITH THE  MODE  SWITCH  IN  THE  MANUAL  POSITION.  EQUIPMENT  DAMAGE COULD RESULT IF CAUTION IS NOT OBSERVED. PLACE THE MODE SWITCH IN THE DESIRED OPERATING POSITION. POSITION THE OVER TEMPERATURE RESET SWITCH TO THE ON POSITION. DO NOT ALLOW LOAD BANK AND GENERATOR SET LOAD TO EXCEED THE  RATED  LOAD  OF  THE  GENERATOR  SET.  EQUIPMENT  DAMAGE COULD RESULT IF CAUTION IS NOT OBSERVED. POSITION THE LOAD SELECTOR SWITCH TO THE PERCENT LOAD WHICH, WHEN ADDED TO THE GENERATOR SET LOAD, WILL MOST NEARLY EQUAL. BUT NOT EXCEED, 100 PER- CENT  OF  THE  GENERATOR  SET  RATED  LOAD. CHECK THAT LOAD BANK POWER ON INDICATOR LIGHT IS LIT, IF IT IS NOT, PRESS IN ON THE LENS. IF THE LAMP ILLUMINATES BUT GOES OUT WHEN RELEASED, RETURN THE LOAD SELECTOR SWITCH TO THE OFF POSITION, NOTIFY MAINTENANCE PERSONNEL. TO REMOVE THE LOAD BANK FROM OPERATION, POSITION THE LOAD SELECTOR SWITCH TO THE OFF POSITION AND PLACE THE OVER TEMPERATURE RESET SWITCH TO THE OFF POSITION. Figure  2-13.  Operating  the  Load  Bank

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing