ARMY TM 9-6115-464-12
AIR FORCE TO 35C2-3-445-1
NAVY NAVFAC P-8-624-12
Section Il. MAINTENANCE ALLOCATION CHART FOR 15KW, TACTICAL, PRECISE AND
UTILITY, 50/60 AND 400 HZ - Continued
(1)
GROUP
NUMBER
(2)
COMPONENT/
ASSEMBLY
Control Box
Assembly
Wiring Harness
Voltmeter, ac
Wattmeter, ac
Ammeter, ac
Wattmeter
Converter
Rheostats/
Potentiometer
Frequency Meter
Frequency
Transducer
Switches
Gauges
Hourmeter
(3)
MAINTENANCE
FUNCTION
Inspect
Test
Replace
Repair
Inspect
Replace
Repair
Rebuild
Inspect
Test
Adjust
Replace
Inspect
Test
Adjust
Replace
Inspect
Test
Adjust
Replace
Inspect
Test
Replace
Inspect
Test
Replace
Inspect
Test
Adjust
Replace
Inspect
Test
Replace
Inspect
Test
Replace
Inspect
Test
Replace
Inspect
Test
Replace
C
.1
.1
.1
.1
.1
.1
.1
.1
.1
.1
(4]
MAINTENANCE LEVEL
DS
GS
O
F
H
1.0
1.5
1.5
1.5
.1
1.0
2.0
1.0
.5
.5
.5
.5
.5
.5
.1
.5
.5
.1
.2
.5
.5
.2
.2
.1
.5
.2
.2
.2
.2
.2
.2
.2
DEPOT
D
(5)
TOOLS AND
EQUIPMENT
2
2
2
(6)
REMARKS
C
A, H
E
C, E
C, E
C, E
F
C
F
F
C
C