Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Tabulated Data (cont)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Tabulated Data (cont)
Up
TM-9-6115-464-12 Wrench Impact Hydraulic Model MV-12-140T Manual
Next
Table 1-1. Differences in Performance Characteristics

ARMY TM 9-6115-464-12 AIR FORCE TO 35C2-3-445-1 NAVY  NAVFAC  P-8-624-12 (d) Load bank kit: DOD drawing number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   72-2803 Load rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7.5 KW Operating voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120/208 or 240/416 Vac 3 Phase 4 wire (e)  Applications  kit: MERADCOM drawing number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13220E8189 Load rating . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  840 watts Operating voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24 Vdc (f)  Acoustic  suppression  kit: Model number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   MEP-004AAS Weight increase to generator set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1292 lb. Cube of generator set with kit installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178.2 cubic feet (15) (16) (17) (18) (19) (20) (21) (22) Fuel System Diagram. Refer to Figure 1-7. Hydraulic System Diagram. Refer to Figure 1-12. AC  and  DC,  15  and  30KW,  50/60  and  400  Hz,  Precise  and  Utility,  Wiring  Diagram,  Dwg.  No. 72-2205. Refer to figure FO-1. AC Schematic Diagram, 15 and 30 KW, Precise Generator Sets, Dwg. No. 72-2200. Refer to figure FO-2. DC Schematic Diagram, 15 and 30 KW, Precise Generator Sets, Dwg. No. 72-2269. Refer to figure FO-3. AC  Schematic  Diagram,  15  and  30KW,  Utility  Generator  Sets,  Dwg.  No.  72-2295.  Refer  to  figure  FO-4. DC  Schematic  Diagram,  15  and  30KW,  Utility  Generator  Sets,  Dwg.  No.  72-2277.  Refer  to  figure  FO-5. Shipping Dimensions and Weights. Refer to Figure 1-3. 1-12  DIFFERENCES  BETWEEN  MODELS.The primary differences between the models of the generator sets covered in this manual are as follows: a. b. c. d. e. f. 1-12 Models  MEP-004A  and  MEP-103A  are  equipped  with  a  50/60  Hz  generator.  Model  MEP-113A  is equipped with a 400 Hz generator. Models MEP-103A and some MEP-113A use an electro-hydraulic governor. Other Models MEP-113A use an electric govemor. Model MEP-004A uses a mechanical governr which is integral with the fuel injection pump. The control cubicle of all three models have a frequency adjust rheostat, but it is functional only on models MEP-103A  and  MEP-113A.  Model  MEP-004A  accomplishes  frequency  adjustment  through  the  manual speed control. All three models use the same special relay box, but models MEP-103A and MEP-113A are also equipped with a precise relay box. The two precise relay boxes are identical with the exception that the precise relay box of model MEP-103A contains a frequency selector switch whereas the precise relay box of model MEP-113A  does  not. Models MEP-103A and MEP-004A use the same exciter regulator assembly and crosscurrent transform- er.  These  components  are  different  on  model  MEP-113A. Differences in performance characteristics are given in Table 1-1.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing