TM5-6115-634-14&P NAVFAC  P-8-647-14&P T0-35C2-3-445-14 TM-6115-14&P/1 MAINTENANCE OF CONNECTOR PLATE 4-17. REPLACE CONNECTOR PLATE This task covers: a. Removal b. Installation INITIAL  SETUP Equipment Conditions: Reference Para. 4-9 General Instructions. Tools General Mechanic’s Tool Kit 5180-00-177-7033 Materials/Parts Connector Plate 97403-13228E1902 NOTE Replacement of the connector plate requires removal of the mounted cable heads and generator  ground. Proceed is  follows: REMOVAL 1. 2. OPEN LEFT REAR ACCESS DOOR. Open door access, left rear on generator set, to allow easy access to rear of connector plate. REMOVE GROUND CABLE. a. Remove brass nut (1), self- locking. b. Tag and remove ground wires (3) and three flat washers (2). 4-21