Page Title: Figure 4-11. Component Assembly Panel, Relay K1 and K50, Test Setup
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 4-10.  Component Base Assembly, Exploded View
Up
TM-5-6115-593-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 600 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Figure 4-12.  AC-DC Control Relay Assembly, Test Setup

TM5-6115-593-34 NAVFAC P-8-631-34 TO-35C2-3-463-2 Figure 4-11.  Component Assembly Panel, Relay K1 and K50, Test Setup replaced,   carefully   solder   new component into place. (g) Install   relay   assembly   (18)   by securing  brackets  (20)  to  shelf (21) using screws (19). (h) Connect wires to terminal boards, then remove wire tags. 4-25.    TIME  DELAY  MODULES  TD1  AND  TD3.    Time delay  module  TD1  (15,  figure  4-10)  delays  crank  limit relay K19 turn on by 30 seconds.  Time delay TD3 (12) times on and off periods averaging 5-second delays and controls recrank inhibit relay K6. a. Tests for Replaceable Components. Check the following components on TD1 and TD3: (1) Check  transistor  Q1  (10,  figure  4-13 and  16,  figure  4-14)  by  connecting  a transistor tester for current gain of 100 minimum, leakage, or short. (2) Check  transistors  Q2  and  Q3  (5  and 4,  figure  4-14)  by  connecting  each  to a    transistor    tester    and    testing    for current gain of 40 minimum, leakage, or short. (3) Check  capacitors  (C1  and  C2  (6  and 7,  figure  4-13)  by  connecting  each  to a   capacitor   tester   and   checking   for leakage  and  capacitance.    C1  must read    10    microfarads,    25    volts    ±5 percent. CR2 must read 47 microfarads, 50 volts ±10 percent. (4) Check  capacitor  C1  (10,  figure  4-14) by   connecting   to   a   capacitor   tester and checking for leakage and capacitance.        Cl    must    read    300 microfarads, 30 volts, ±5 percent. (5) Check   resistors   using   an   ohmmeter for the following resistance’s: 4-21