Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: TABULATED DATA
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
CHAPTER 1 INTRODUCTION
Up
TM-5-6115-593-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 600 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
TABULATED  DATA (cont)

TM5-6115-593-34 NAVFAC P-8-631-34 TO-35C2-3-463-2 components  of  the  generator  set  are  provided  in  the applicable maintenance paragraphs of this manual. 1-7.    TABULATED  DATA.    This  paragraph  contains  all maintenance data pertinent to intermediate (field) (direct and general support) and depot maintenance personnel. The   generator   set   has   identification   and   instructional plates   located   throughout   the   set.      The   information pertaining to these plates is contained in the Operator/Crew and Organizational Maintenance manual. a.  Generator Set. Manufacturer .................................. Fermont Division, Dynamics Cor- poration of America DOD Drawing Number... ................. 76-029 Model ............................................. MEP-029B Mode .............................................. 50/60 Hertz 3 phase, 4 wire Class .............................................. Utility b.  External Power Box Assembly. Starter Motor Contactor DOD Drawing Number .............. 76-11254 Contact Rating Volt .................................... hp 200 ............... ..................... 10 230 ................ .................... 15 380-575 ........... .................. 25 Overload trip ...... ............................ 35.5 to 38.2 amps Nominal operating........................... .120V AC, 50/60 Hz Required operating.......................... 50 Hz nominal from ranges 110 to 123V AC and from 47.5 to 52.5 Hz 60 Hz nominal from 114 to 144V AC and from 57.5 to 62.5 Hz c.  AC-DC Control Box Assembly. Battery Charger DOD Drawing Number.. ............ 76-11207 AC Input ............. ..................... 120V AC, 50/60 Hz DC Output ................................ 24V DC, 20 amps Fuse protection ..... ................... AC input and DC output Diodes, zener (measured with associated resistor) CR1 (TD1) ........ ....................... .6.8 volts CR4 (TD3) ......... ...................... 15 volts Resistors R116 ........................................ 5 ohms, 14 watts, +5 percent R4 (TD1) .................................. 820 ohms, 25 watts +5 percent       R1 (TD1) 2 k, 1 watt, +5 percent R2 (TD1) .................................. 2.7 megohms, 25 watts, +5 percent R1 (TD3) .................................. 2 k, 1 watt, +5 percent R2 (TD3) .................................. 2 k, 1 watt, +5 percent R4 (TD3) .................................. 2 k, 0.25 watt, +5 percent R7 (TD3) .................................. 20 k, 0.25 watt, +5 percent R6 (TD3)................................... 200 ohms, 1 watt, +5 percent R5 (TD3) .................................. 68 k, 0.25 watt, +5 percent R3 (TD3) .................................. .6 k, 0.25 watt, +5 percent Capacitors C1 (TD1) .................................. 10 microfarads, 25 volts, +5 per-cent C2 (TD1) ........... ............................. 47 microfarads, 50 volts, +5 per-cent C1 (TD3) ........... ............................. 300 microfarads, 30 volts, ±5 per-cent Governor Controller DOD Drawing Number... ........... 76-11208 Inputs ....................................... 90 to 240V AC, 3 phase load sensing 24V DC supply, 10 watts con- sumption 900 to 2700 rpm speed range Output ............................................ Voltage to actu- ator 0 to 8V DC Operating range .............................. 40 to 160°F (-40 to 71°C) Voltage Regulator DOD Drawing Number .............. 76-11209 Power input............................... 120V AC, 50/60 Hz 840VA Output rating............................. 62.5V DC, 7 amps mas continuous; 90V DC, 10 amps 1 minute forcing Sensing..................................... 208V AC, 3 phase, 50/60 Hz Voltage regulation..................... +1/2 percent Response time ......................... T6 milliseconds d.  Control Cubicle Assembly. Alarm Horn DOD Drawing Number... ........... 76-11225 Input .................. ...................... 24V DC Output ...................................... 370 cycles per second, audible 1-2

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing