Figure 2-12.  Single Generator Unit, Operating Instructions with Housing Kit Installed
Up
TM-5-6115-593-12 Power Plant Utility (MUST) Gas Turbine Engine Driven (AMERTECH Corp Model APP-1) Manual
Next
Figure 2-13.  Remote Control Module Panel

TM 5-6115-593-12 TO 35C2-3-463-1 2-10.    OPERATION  WITH  THE  REMOTE  CONTROL  MODULE  AND  CABLE.    Addition  of  the  remote  control  module and cable allows operation of the engine/generator set from distances of up to 100 feet (30 meters).  The purpose and location of controls on the remote control module panel are described in table 2-5 and illustrated in figure 2-13.  It should be noted that the controls on the remote control module are almost identical to those on the generator control panel. a.  Connection Procedure for Using Remote Control Module and Cable. WARNING Do not attempt to make connections to the control cubicle while generator set is in operation. (1)  Connect the remote control cable to the remote control module by connecting plug P4 to receptacle J4, plug P1 to receptacle J1, and plug P2 to receptacle J2. (2)    Connect  the  other  end  of  the  remote  control  cables  to  the  back  side  of  generator  set  control  cubicle  by connecting plug P4 to receptacle J4, plug P1 to receptacle J1, and plug P2 to receptacle J2. (3)  Remove terminal board jumper connections in control cubicle as shown in figure 2-14. b.    Use  of  Remote  Control  Module.    Figures  2-15,  2-16,  2-17,  and  2-18  provide  preparation,  starting,  stopping  and operating instructions for generator set equipped with a remote control module. c.    Emergency  Stopping.    To  stop  the  generator  set  from  the  remote  control  module  in  an  emergency,  place  the EMERGENCY SHUT-DOWN switch in the ON position. Table 2-5.  Remote Control Panel, Controls and Instruments FIGURE, NORMAL INDEX NO. CONTROL AND INSTRUMENT FUNCTION READING/SETTING 2-13,1 VOLT ADJ INCREASE- Permits adjustment of Neutral DECREASE generator set voltage output. 2-13,2 BATTLE SHORT lamp Indicates BATTLE SHORT OFF switch is ON. 2-13,3 VOLTMETER-BUSS VOLT-GEN Selects BUSS 1-2, GEN —   — VOLT switch 1-2, GEN 2-3, BUSS 2-3, GEN 3-1, and BUSS 3-1. 2-13,4 FREQ ADJ INCREASE- Switch to adjust gene- Neutral DECREASE rator at frequency 2-13,5 VOLTS AC meter Indicates AC output 120/208 or voltage. 240/416 2-13,6 HERTZ frequency meter Indicates generator set. 50 Hz: 48.2- frequency in Hz. 51.8 Hz 58.2 60 Hz: 61.8 Hz 2-13,7 AMMETER switch Selects phase 1, 2 or 3. As desired. 2-28