Page Title: Table 2-3. AC-DC Control Panel, Controls and Instruments
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Table 2-2.   Generator Control Panel, Controls and Instruments-Continued
Up
TM-5-6115-593-12 Power Plant Utility (MUST) Gas Turbine Engine Driven (AMERTECH Corp Model APP-1) Manual
Next
Figure 2-3. AC-DC Control Panel

TM 5-6115-593-12 TO 35C2-3-463-1 Table 2-2.   Generator Control Panel, Controls and Instruments-Continued FIGURE, INDEX NO. CONTROL AND INSTRUMENT FUNCTION NORMAL READING/SETTING 2-2,33 VOLT ADJ INCREASE- DECREASE switch Switch    to    adjust    generator    set voltage.- Neutral 2-2,34 FREQ ADJ INCREASE- DECREASE switch Switch    to    adjust    generator    set frequency Neutral 2-2,35 HERTZ frequency meter Indicates  generator  set  frequency in Hz 50Hz:  48.2-51-8 Hz 60 Hz: 58.2-61.8 Hz 2-2,36 1-3-2 lamp Lights  to  indicate  phase  sequence 1,3,2 OFF 2-2,37 VOLTMETER-BUSS     VOLT-     GEN VOLT switch Selects BUSS 1-2, GEN 1-2, GEN 2-3,    BUSS    2-3    GEN    3-1,    and BUSS 3-1. —   —   — 2-2,38 PHASE     SEQUENCE-BUSS-     OFF switch Selects buss, generator, or off. —  —  – Table 2-3.   AC-DC Control Panel, Controls and Instruments FIGURE, INDEX NO. CONTROL AND INSTRUMENT FUNCTION NORMAL READING/SETTING 2-3,1 120V RECEPTACLE BREAKER RECEP. Controls power to CONV ON 2-3,2 REACTIVE LOAD COMPENSATION CONTROL - Adjusts   reactive   load   sharing   of generator sets in parallel. —   —   — 2-3,3 EMERGENCY SHUTDOWN-ON- OFF switch Shuts   down   generator   set   during an   emergency   and   activates   air boxes on engine. OFF 2-3,4 FREQUENCY SELECTOR 50 Hz-60 Hz switch Selects either 50 Hz or 60 Hz —   —   — 2-3,5,6 REACTIVE LOAD COMPENSATION receptacles - Receptacles to interconnect voltage regulators. —   —   — 2-3,7,8,9 GOVERNOR PARALLELING CIRCUIT receptacles Receptacles to interconnect governors for paralleling generator sets with paralleling cables. —   —   — 2-3,10 REACTIVE LOAD COMPENSATION receptacle - With  shorting  plug  in  place  allows droop voltages parallel operation. —   —   — 2-3,11 FREQUENCY DROOP- ISOCHRONOUS switch Allows selection of either droop or isochronous operation. —   —   — 2-8