Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: TABULATED DATA
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 1-7.  Housing Kit, Installed on Generator Set
Up
TM-5-6115-593-12 Power Plant Utility (MUST) Gas Turbine Engine Driven (AMERTECH Corp Model APP-1) Manual
Next
TABULATED DATA (cont)

TM 5-6115-593-12 TO 35C2-3-463-1 Transfer Contactor DOD Drawing Number ..... 76-11203 Type  ............................... AC reversing, open, NEMA Size 2 Coil voltage ..................... 120V AC, 50/60 Hz, 3 pole, electrically and mechanically interlocked d. AC-DC Control Box Assembly. AC-DC Control Relay Assembly DOD Drawing Number ..... 76-11300 Eight relays ..................... 10 amp, DPDT Type  ............................... .M5757/23-003 (MIL-R-5757) Battle Short and Run-Stop Relays DOD Drawing Number ..... 76-11302 Type ................................ 24V DC coil, 14 pin, 6 pole (4 pole NO, 2 pole NC) Contacts  ......................... 10 amp Fuel Transfer Pump Relay DOD Drawing Number ..... 70-1140 Type  ............................... 24V DC coil, 50 to 60 ohms Contacts  ......................... 50 amp, 2 NO contacts Integrated Time Delay Modules DOD Drawing Number ..... 76-11304-1 and 76-11305 Types .............................. 76-11304-1 24V DC, 30 second turn on delay 76-11305 24V DC, times on and off periods averaging 5 second delay Manual Potentiometer DOD Drawing Number ..... 76-11210 Type  ............................... Wire wound, 500 ohm Power rating .................... 2 watts at 158°F (70°C) 0 watts at 248°F (125°C) Shunt  .............................. MS91586-1 Type  ...............................   MSA300 Current rating .................. 30 amps Voltage rating .................. 50 millivolts Motor Operated Potentiometers DOD Drawing Number ..... 76-11213 and 76-11214 76-11213 Resistance ...................... 500 ohm, 3 watt, 3 turn Motor .............................. 24V DC, re- versing, 1/20 hp Clutch ............................. Adjusted for 20 ±5 inch-ounces (0.08 joules) torque 76-11214 Resistance ...................... 250 ohm, 3 watt, 3 turn Motor .............................. 24V DC, re- versing, 1/20 hp Clutch ............................. Adjusted for 20 ±5 inch-ounces (0.08 joules) torque e.  Control Cubicle Assembly Frequency Transducer DOD Drawing Number ..... 69-578 AC input  ......................... 120V AC, single phase, 50/60 Hz NOTE Transducer  and  meter  furnished  only  as  a matched set which consists of the transducer and frequency meter. Thermal Watt Converter DOD Drawing Number..69-589 Volts ............................... 100/130V AC Current  ........................... 1 ampere Elements  ........................ 3 Phase  ............................. 3 Number of wires   ............ 4 Output  ............................ 20MV DC, open circuit Output circuit  .................. 4.97 ohms resistance Watts per element .................. 96.26 Accuracy  ............................... Measure 1 percent full scale Potential Transformer DOD Drawing Number ..... 76-11237, 600V AC 25VA at 50/60 Hz Secondary volts ..................... 115V AC Voltage Input with Primary Connected: Parallel  ........................... 240 input Series  ............................. 480 input Voltage output  ....................... 120 output secondary 1-10

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing