Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: TM-5-6115-585-12_90
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
TM-5-6115-585-12_89
Up
TM-5-6115-585-12 Generator Set Diesel Engine Driven Tactical Skid Mtd 5 KW 1 Phase 2 Wire 1 Phase-3 Wire 3 Phase-4 Wire 120 120/240 and 120/208 Volts Manual
Next
TM-5-6115-585-12_91

T M 5 - 6 1 1 5 - 5 8 5 - 12 N A V F A C     P - 8 - 6 2 3 - 1 2 T O - 3 5 C 2 - 3 - 4 5 5 - 1 T M - 0 5 6 8 4 C / 0 5 6 8 5 B - 12 F i g u r e    3 - 1 1 .    C l e a n i n g    A i r    F i l t e r    E l e m e nt D o    n o t    r e - u s e    e l e m e n t    m o r e    t h a n    t w i c e .    Do not    re-use    element    if    it    has    even    the    slightest r u p t u r e . c .      I n s t a l l a t i o n . (1)   Air   Cleaner   Element.   Slide   element   (4,   figure 3-10)   over   stud   in   housing   (5),   install   seal   (3)   on   wing n u t     ( 2 )     a n d     s e c u r e     e l e m e n t     w i t h     w i n g     n u t     ( 2 ) .     H a n d tighten   wing   nut.   Install   seal   (9)   and   dust   cap   (1).   Be c e r t a i n     “ T o p ”     o n     d u s t     c a p     f a c e s     u p .     R e t i g h t e n     c l a m p ( 1 0 )     t o     s e c u r e     d u s t     c a p .     D e p r e s s     r e s e t     b u t t o n     ( 8 )     t o r e s e t     i n d i c a t o r     ( 7 ). 3 - 1 9 .    C O N T R O L    C U B I C L E    A S S E M B L Y. a.    Inspect    (see    figure    3-12). (1)   Control   Cubicle   Assembly.   Inspect   cubicle   for d i r t ,     g r e a s e     o r     p h y s i c a l     d a m a g e     w h i c h     m i g h t     a f f e ct o p e r a t i o n     o f     t h e     u n i t .     L o o s e n     t h r e e     f a s t e n e r s     h o l d i n g c o n t r o l     p a n e l     t o     p e r m i t     a c c e s s     t o     t h e     i n s i d e     o f     t h e c u b i c l e .     C h e c k     t o     s e e     t h a t     a l l     p a r t s     m o u n t e d     t o     t h e c u b i c l e    a r e    s e c u r e    a n d    a l l    h a r d w a r e    i s    i n    p l a c e . C h e c k     t h a t     a l l     i n s t r u m e n t s     a n d     c o n t r o l s     o p e r a t e     n o r- mally   when   unit   is   running.   Check   for   broken   or   badly i n s u l a t e d     h a r n e s s     w i r e s     a n d ,     i f     n e c e s s a r y ,     r e f e r     to higher    level    of    maintenance. ( 2 )     P a n e l     L i g h t     A s s e m b l i e s     ( D S 1     a n d     D S 2 ) .     I n - s p e c t    p a n e l    l i g h t    a s s e m b l i e s    ( 1 )    f o r    c r a c k e d    o r    m i s s - i n g      l a m p      c o v e r s . C h e c k      t h a t      e l e c t r i c a l      c o n n e c t i o n s are   clean   and   tight. ( 3 )    P a n e l    L i g h t    S w i t c h .    O p e r a t e    l a m p    s w i t c h    ( 2) to    check    that    lamps    are    operable. ( 4 )     M e t e r s .     B a t t e r y     I n d i c a t o r     ( M 1 ) ,     H o u r m e t er ( M 2 ) ,     F r e q u e n c y     M e t e r     ( M 3 ) ,     P e r c e n t     C u r r e n t     M e t er ( M 4 )    a n d    A C    V o l t m e t e r    ( M 5 ) .    I n s p e c t    m e t e r    g l a s s    t o s e e    t h a t    i t    i s    n o t    c r a c k e d .    C h e c k    t o    s e e    t h e    m e t er f a c e    i s    c l e a n    a n d    r e a d a b l e .    C h e c k    t o    s e e    t h a t    p o i n t er i s     n o t     b e n t .     C h e c k     t o     s e e     t h a t     e l e c t r i c a l     c o n n e c t i o ns are   clean   and   tight. ( 5 )    D C    C o n t r o l    C i r c u i t    B r e a k e r    ( C B 2 ) .    I n s p e ct c i r c u i t     b r e a k e r     f o r     p h y s i c a l     d a m a g e .     I n s p e c t     e l e c t r i- c a l    c o n n e c t i o n s    t o    s e e    t h a t    t h e y    a r e    c l e a n    a n d    t i g h t. C h e c k     t o     s e e     t h a t     w h e n     b u t t o n     o n     b r e a k e r     i s     p u s h e d in   or   pulled   out,   it   will   remain   in   that   position. (6)   Master   Rotary   Switch   (S1).   Inspect   switch   for p h y s i c a l     d a m a g e .     I n s p e c t     e l e c t r i c a l     c o n n e c t i o n s     t o s e e     t h a t     t h e y     a r e     c l e a n     a n d     t i g h t .     C h e c k     t o     s e e     t h at when   placed   in   the   OFF,   PRIME   &   RUN   AUX   FUEL, or   PRIME   &   RUN   positions   the   switch   will   remain   in p o s i t i o n .    C h e c k    t o    s e e    t h a t    w h e n    p l a c e d    i n    t h e    P R E- H E A T     p o s i t i o n     a n d     r e l e a s e d ,     s w i t c h     r e t u r n s     t o     O F F p o s i t i o n .     W i t h     D C     C o n t r o l     C i r c u i t     B r e a k e r     ( C B 2) pulled   out   (unit   will   not   crank),   check   to   see   that   when r e l e a s e d     f r o m     S T A R T     p o s i t i o n     t h e     s w i t c h     w i l l     a u t o- matically   return   to   PRIME   &   RUN   position. ( 7 )     P a n e l     L i g h t     S w i t c h     ( S 2 ) .     I n s p e c t     s w i t c h     f or p h y s i c a l     d a m a g e .     I n s p e c t     f o r     c l e a n     a n d     t i g h t     e l e c- t r i c a l     c o n n e c t i o n s .     C h e c k     t o     s e e     t h a t     s w i t c h     w i l l     r e- main   in   both   ON   and   OFF   positions. (8)   Range   Selector   Switch   (S6).   Inspect   switch   for p h y s i c a l     d a m a g e .     I n s p e c t     f o r     c l e a n     a n d     t i g h t     e l e c- t r i c a l     c o n n e c t i o n s .     C h e c k     t o     s e e     t h a t     s w i t c h     w i l l     r e- main   in   each   of   the   six   switch   positions. ( 9 )     V o l t a g e     A d j u s t     R h e o s t a t     ( R 1 ) .     I n s p e c t     r h e o - s t a t    f o r    p h y s i c a l    d a m a g e .    I n s p e c t    f o r    c l e a n    a n d    t i g ht e l e c t r i c a l      c o n n e c t i o n s .      N o t e      r h e o s t a t      p o s i t i o n      a nd c h e c k     t h a t     r h e o s t a t     m o v e s     s m o o t h l y     t h r u     i t s     r a n g e. Return    rheostat    to    previously    noted    position. (10)    AC    Voltage    Regulator    (A2).    Visually    inspect b o a r d     a n d     c o m p o n e n t s     f o r     s i g n s     o f     o v e r h e a t i n g, c l e a n l i n e s s     a n d     p h y s i c a l     d a m a g e .     I n s p e c t     f o r     c l e an a n d    t i g h t    c o n n e c t i o n s    t o    t h e    b o a r d    a n d    t h a t    b o a r d    is s e c u r e l y  m o u n t e d. ( 1 1 )     T r a n s f o r m e r s     ( T 1     a n d     T 2 ) .     I n s p e c t     t r a n s - f o r m e r s     f o r     p h y s i c a l     d a m a g e ,     c l e a n l i n e s s     a n d     t h at e l e c t r i c a l    c o n n e c t i o n s    a r e    c l e a n    a n d    t i g h t. ( 1 2 )    W i r i n g    H a r n e s s .    I n s p e c t    w i r i n g    h a r n e s s    f or p h y s i c a l     d a m a g e     s u c h     a s     b r o k e n     o r     f r a y e d     w i r e s     or d a m a g e d     i n s u l a t i o n. ( 1 3 )    C o n t r o l    C u b i c l e    B o x .    I n s p e c t    b o x    f o r    p h y s- i c a l     d a m a g e. Change   2 3 - 1 7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing