Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: TM-5-6115-585-12_67
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
TM-5-6115-585-12_66
Up
TM-5-6115-585-12 Generator Set Diesel Engine Driven Tactical Skid Mtd 5 KW 1 Phase 2 Wire 1 Phase-3 Wire 3 Phase-4 Wire 120 120/240 and 120/208 Volts Manual
Next
TM-5-6115-585-12_68

warning TM  5-6115-585-12 NAVFAC    P-8-262-12 TO-35C2-3-455-1 TM-05684C/05685B-12 k.   During   operation,   listen   for   unusual   noises which   may   indicate   a   pending   malfunction. 2 - 5 .     O P E R A T I N G     I N     A L T E R N A T E     M O D E S. When   selecting   position   120V,   1   PH   unit   is i n    2    w i r e    c o n f i g u r a t i o n .    A    s i t u a t i on can/may  exist  in  allowing  a  double  fault  to occur.   To   eliminate   this   possibility   the reconnection   switch   will   be   rewired   by   us- ing   a   AWG   #4   wire   jumper   between   ter- minals   #LO   and   #6   of   section   9. 2 - 6 .    S H U T T I N G    D O W N    U N I T . a.   Place   AC   circuit   breaker   in   the   OFF   position. b.   To   stop   the   Generator   Set,   place   the   master switch   in   the   OFF   position. c.   After   operation   of   the   Generator   Set,   perform the   inspection   and   service   requirements   as   outlined   in preventive   maintenance   checks   and   services   under Operator   Maintenance   Instructions,   Chapter   3. d.   Emergency   Stop. To   stop   Generator   Set   in   an emergency,   pull   out   DC   control   circuit   breaker   (see figure   2-3). e.   If   generator   set   is   not   going   to   be   operated   for two   weeks   or   more,   disconnect   the   negative   cable   from the  battery.  The  generator  set  will  be  ready  to  go  upon reconnection   of   the   negative   cable. C A U T I O N Disconnect   load   before   switching. This   unit   can   be   set   for   120   volt–1-phase,   120/240 v o l t — 1 - p h a s e ,    o r    1 2 0 / 2 0 8    v o l t — 3 - p h a s e    o u t p u t. Rotate   reconnection   switch   to   desired   output   connec- tion.   Refer   to   figure   2-2. S e c t i o n    II O P E R A T I O N    U N D E R    U N U S U A L    C O N D I T I O NS 2 - 7 .     O P E R A T I O N     I N     E X T R E M E     H E A T. To   ensure   satisfactory   operation   under   conditions   of extreme   heat,   accomplish   the   following. a.   Be   sure   that   nothing   obstructs   air   flow   to   and from   the   unit. b.   Keep   cooling   fins   clean. c.   Inspect   battery   electrolyte   level   daily.   Add distilled   water   if   necessary. d.   Keep   generator   free   of   dirt   and   grime.   Be   sure ventilating   screens   are   free   of   obstructions. 2 - 8 .    O P E R A T I O N    I N    E X T R E M E    C O L D    ( - 2 5 ° F, -32°C). To   ensure   satisfactory   operation   under   conditions   of extreme   cold   accomplish   the   following a.   Use   correct   lubricating   oil   in   engine   crankcase for   temperature   conditions.   (Refer   to   figure   3-1.) Change   oil   only   when   engine   is   warm. b.   Use   Arctic   Grade   diesel   fuel. c.   Keep   batteries   in   a   well   charged   condition. d.   Be   certain   air   cleaner   intake   control   is   in   cold weather   position. e.   Shutter   blades   should   be   fully   closed   for   cold engine,   open   only   partially   under   light   load,   open   more as   load   increases. f.   Hold   master   switch   in   START   position   for  2 minutes   after   engine   comes   to   operating   speed. 2 - 9 .    O P E R A T I O N    I N    D U S T Y    O R    S A N DY A R E A S . To   ensure   that   the   Generator   Set   will   operate   satisfac- t o r i l y    i n    d u s t y    o r    s a n d y    a r e a s ,    a c c o m p l i s h    t he f o l l o w i ng a.   Clean   Generator   Set   frequently. b.  Service  air  cleaner  frequently.  Check  air  restric- tion   indicator   daily.   If   red   signal   is   visible,   service   the air   cleaner.   Be   certain   that   all   air   cleaner   and   intake manifold  connections  do  not  leak.  Be  certain  oil  filler cap  fits  snugly. c.   Change   crankcase   oil   and   oil   filter   frequently. d.   Store   oil   and   fuel   in   dust-free   containers. e.   Make   sure   that   Generator   Set   ground   connec- tion   is   free   of   dust   and   sand   and   connections   are   tight before   starting   the   unit. 2-10.   OPERATION   IN   WET   OR   HUMID   AREAS. To   ensure   that   the   Generator   Set   will   operate   satisfac- torily   in   wet   or   humid   areas,   accomplish   the   following 2-6 Change   6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing