Table  6-3.  AC  Output  Control  Box  Wiring  Harness
Up
TM-5-6115-584-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Remove

TM    5-6115-584-34 NAVFAC    P-8-622-34 TO-35C2-3-456-2 Table 6-3. AC Output Control Box Wiring Harness (Cont) Wire No. X21A12 X22A16 X23A16 X28A16 X29A16 X30A16 X30B16 X30C16 X31A16 X31B16 X32A16 X33A X34A X34A X36A X37A X38A X39A X40A X47A X48A X49A 16 16 16 16 16 16 16 16 16 16 16 X76A16 X77A16 X31F16 Gauge 12 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Marking Color black black black black black black black black black black black black black black black black black black black black black black black black black (4)  AC  Voltmeter  (M5)  (18,  figure  6-3).  Tag  and disconnect  two  leads  from  meter.  Remove  three  screws, nuts, and lockwashers attaching meter to control panel and remove meter. d.   Meters   (replace). (1) Frequency Meter (M3) ( 16, figure 6-3). Position meter  in  control  panel  and  attach  with  three  screws,  lock- washers,  and  nuts.  Connect  the  two  electrical  leads  and remove  tags. (2)  Frequency  Transducer  (A3)  (56,  figure  6-3). Position  transducer  to  back  of  control  cubicle  and  attach with four screws (54) and nuts (55). Connect the four electri- cal leads and remove tags. (3)  Percent  Current  Meter  (M4)  (17,  figure  6-3). Position   meter   on   control   panel   and   attach   with   three screws,  lockwashers  and  nuts.  Attach  the  two  electrical  leads and  remove  tags. (4)  AC  Voltmeter  (M5)  (18,  figure  6-3).  Position meter on control panel and attach with three screws, lock- washers,   and   nuts.   Attach   the   two   electrical   leads   and remove  tags. Length in  Inches 10 20 15.5 14 19.5 14 15 32 7 22 16 14.5 17 19 28 28 25 26 21 22 20.5 16 16 34 35 Terminal  Lugs MS25036-156,MS25036-156 MS25036-153 MS25036-153 MS25036-153,  MS25036-153 MS25036-153 MS25036-153, MS25O36-107 MS25036-107,  MS25036-108 MS25036-153,  MS25036-107 MS25036-107,  MS25036-153 MS25036-107 MS25036-153,  MS25036-108 MS25036-153,  MS25036-153 MS25036-153 MS25036-153 MS25036-153,  MS25036-153 MS25036-153,  MS25036-153 MS25036-153,  MS25036-153 MS25036-153 MS25036-153 MS25036-107,  MS25036-153 MS25036-107,MS25036-153 MS25036-107,MS25036-153 MS25036-153,  MS25036-108 MS25036-153 MS25036-107,  MS25036-153 6-5.  GENERATOR  SET  WIRING  HARNESS. a. Remove  (see  figure  6-2).  Refer  to  figure  6-2  and remove  wiring  harness  at  terminal  boards  and  connectors. On  ASK  equipped  generators,  refer  to  Operator  and  Organi- zational Maintenance Manual and remove cover assembly. b.  Repair.  Replace  wires  and  terminals  as  needed.  See table 6-2. c. Install (see figure 6-2). Refer to figure 6-2 and install wiring harness at terminal boards and connectors. On ASK equipped  generators,  refer  to  the  Operator  and  Organiza- tional Maintenance Manual and install cover assembly. 6-6.   VOLTAGE   REGULATOR. a. Test, on Equipment. (1)   Operate   set   at   rated   load   and   adjust   output voltage as follows: (a)   Refer   to   figure   6-5   (or   6-5.1)   and   turn adjustment  screw  on  resistor  R15  (or  R16)  counterclockwise until  voltage  becomes  unstable. 6-8 Change 7