Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Table 2-3. Troubleshooting (Cont)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Table   2-3.   Troubleshooting   (Cont)
Up
TM-5-6115-584-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Table   2-3.   Troubleshooting   (Cont)

TM  5-6115-584-34 NAVFAC P-8-622-34 TO-35C2-3-456-2 TM-0568C-34 Table   2-3.   Troubleshooting   (Cont) MALFUNCTION TEST  OR  INSPECTION CORRECTIVE   ACTION 15.  STICKING  VALVES  (CONT). Step   3.   Check   clearance   between   valve   stem   and   guide   (paragraph   7-9). Correct   clearance. 16.  ENGINE  RUNS  NORMALLY  BUT  GENERATOR  HAS  NO  OUTPUT. Step   1.   Check   voltage   regulator   (paragraph   6-6). Repair   or   replace   regulator. Step   2.   Check   exciter   field   (stator)   for   open   or   shorted   windings   (paragraph   8-2). Replace   stator   if   necessary. Step   3.   Check   diodes   on   exciter   rotor   (paragraph   8-2), Replace   diodes   if   necessary. Step   4.   Check   generator   field   (rotor)   for   open   or   shorted   windings Replace   rotor   if   necessary. Step   5.   Check   generator   rotor   flashing   circuit   (paragraph   6-9). Replace   diode   CR2   or   bridge   rectifier. (paragraph    8-2). Step   6.   Check   generator   stator   for   open,   shorted,   or   grounded   windings   (paragraph   8-2). Replace   stator   if   necessary. Step   7.   Check   exciter   rotor   for   open,   shorted,   or   grounded   windings   (paragraph   8-2). Replace   exciter   rotor   if   necessary. Step   8.   Check   bridge   assembly   A4   for   defective   resistor   or   diodes   (paragraph   6-9). Replace   defective   resistor   or   diodes 17.  ENGINE  RUNS  NORMALLY  BUT  GENERATOR  HAS  LOW  OUTPUT. Step   1.   Check   voltage   regulator   (paragraph   6-6). Adjust,   repair,   or   replace   regulator. Step   2.   Check   generator   stator   for   open   or   shorted   windings   (paragraph   8-2), Replace   stator. Step   3.   Check   exciter   rotor   for   shorted   windings   (paragraph   8-2), Replace   rotor. Step   4.   Check   diodes   on   exciter   rotor   (paragraph   8-2). Replace   diodes   as   necessary. 2-10

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing