Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Figure 4-1. Uncrating Generator Set
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
CHAPTER  4 ORGANIZATIONAL MAINTENANCE
Up
TM-5-6115-584-12 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Figure  4-2.  Grounding  Generator  Set

TM  5-6115-584-12 NAVPAC  P-8-622-12 TO-35C2-3-456-1 Figure 4-1. Uncrating Generator Set (9)  Check  crankcase  oil  level  (paragraph  3-2) and  add  oil  as  necessary  (paragraph  3-3)  in  accord- ance with the lubrication order (figure 3-1). 4-2.  INSTALLINGGENERATOR   SET a. General. The engine Generator Set should be in- stalled on a site clear of obstacles, with ample venti- lation and level within ±15 degrees maximum. b. Outdoor Installation. When preparing for a per- manent installation, be sure the base is solid enough to support the weight of the unit. See figure 1-4 for dimensions of the base. Select a location where there will be sufficient space on all sides for servicing and operation of the engine Generator Set. When prepar- ing a temporary installation, move the engine Gener- ator  Set  as  close  to  the  worksite  as  practical.  Use suitable planks, logs, or other material for a base in an area where the ground is soft. c. Indoor Installation, Keep the area well ventilated .t all times, so that the engtne Generator Set will re- ceive  a  maxtmum  supply  of  air.  If  a  free  supply  of fresh  air  is  not  available,  provide  duct  work  which will assure at least 1350 cubic feet of air per minute. 4-2 Change 10 If louvers  are  used  at  the  air  entrance,  increase  the duct work size by 25 to 50 percent. Install a gas-tight metal  pipe  exhaust  from  the  exhaust  outlets  to  the outside  of  the  installation.  The  termination  of  the exhaust  pipe  shall  be  such  that  hot  gases  or  sparks will  be  discharged  harmlessly  and  will  not  be  directed against  combustible  material  or  into  an  area  con- taining flammable gases or vapors. Use as few bends in the pipe and as short a pipe as possible. The ex- haust  pipe  should  include  a  low  point  with  suitable means   for   draining   of   condensate.   Provide   metal shields,  12  inches  larger  in  diameter  than  the  ex- haust pipe where the line passes through flammable walls. Line the exhaust pipe with fiberglass if there is any danger of anyone touching it. Do not operate the engine Generator Set in an enclosed  area  unless  the  exhaust  gases  are piped  to  the  outside.  Inhalation  of  exhaust fumes  will  result  in  serious  illness  or  death. d.  Leveling.  The  Generator  Set  is  a  portable  unit and  is  designed  to  operate  satisfactorily  up  to  15°

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing