Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (Cont.)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Section   III.   PREVENTIVE   MAINTENANCE   CHECKS   AND   SERVICES   (PMCS)
Up
TM-5-6115-584-12 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Table  3-2.  Operator/Crew  Preventive  Maintenance  Checks  and  Services  (Cont.)

B-Before TM 5-6115-584-12 NAVFAC  P-8-622-12 TO-35C2-3456-1 TM-05682C-12 Table  3-2.  Operator/Crew  Preventive  Maintenance  Checks  and  Services  (Cont.) NOTE Within  designated  interval,  these  checks  are  to  be  performed  in  the  order  listed. D-During A-After W-Weekly M-Monthly Item  To  Be Inspected Generator   set (cont.) Controls   and a.   Battery indicator b.   Frequency meter c.   Percent   rated current  meter d.   Voltmeter e.  Oil  pressure gage f.  Fuel  gage Fuel  tank Procedures Check  for  and  have  repaired or  adjusted  as  necessary Equipment   is Not   Ready/ Available  if: c.  Check  that  grounding  cable  is  installed  and tight  (para  4-2e,  fig.  4-2). d.  Check  restriction  indicator;  if  RED,  clean  or replace   air   filter   element.   (para   3-18) NOTE During   starting   and   operation,   check   restriction indicator.  Check  for  leaks,  loose  or  cracked  parts, unusual  noise,  rough-running,  excessive  vibration, lack  of  power,  incorrect  instrument  readings,  or any  indication  of  a  failing  or  defective  component. If   suspected,   notify   organizational   maintenance. Instruments  will  indicate  within  specified  limits. Normal  indication:  yellow  while  charging,  green when  fully  charged. Normal  indication:  60  Hz  (red  line)  with  load on   generator. Normal  indication:  Percent  of  load  (output)  on each  phase.  Not  to  exceed  100%  load  or  5% difference   between   phases. Normal  indication:  120,  208  or  240  volts depending  on  AMP  Volt  transfer  switch  position. Normal  indication:  20  to  45  psig  at  rated  RPM. Normal    indication:    Full Fill  tank  upon  completion  of  operation. Dangerous  gases.  Do  not  smoke  or  use  open  flame while  servicing  battery,  due  to  possible  presence of  hydrogen,  a  highly  explosive  gas. Cable  is  improperly installed  or  missing. Air  cleaner  is missing  or unserviceable. Indicator    indicates red. Indicating   in the   Red. Proper    frequency cannot   be maintained. Desired  voltage cannot   be   obtained. Oil  pressure  drops below 15 psig. Change  6 3-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing