Back Table l-3. Specified Torque Values - (Cont) | Up TM-5-6115-545-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual | Next Table 1-5. Electrical Performance Characteristic Parameters AC Precise (Class 1) |
1-49
Table 1-4. Engine Generator Set Classification
Special
Common
output
Governing
Component
Class
Mode
Name
Frequency
System
Complement
Model
1
I
Tactical
50/60 Hz
Electro-Hydraulic,
Electric governor control unit,
MEP105A
Precise
With backup
hydraulic actuator, hydraulic
manual governor
pump and sump, precise
relay assembly, special
relay assembly, tactical
relay assembly
2
I
Tactical
50/60 Hz
Mechanical
Tactical relay assembly,
MEP006A
Utility
(droop type)
special relay assembly
1
II
Tactical
400 Hz
Electro-Hydraulic,
Electric governor control unit,
MEP115A
Precise
With backup
hydraulic actuator, hydraulic
manual governor
pump and sump, tactical
relay assembly, special
relay assembly
|