Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Alternator.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Short   circuit   relay.
Up
TM-5-6115-545-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Table   1-1.   Time   Standards

p.   Thermal   Wall   Converter,   400   Hz. DOD   drawing   No.   .   .   .   .   .   69-589-2. volts   .   .   .   .   .   .   .   .   .   .   .  100/130. Current   .   .   .   .   .   .   .   .   .   .  1   ampere. Elements   .   .   .   .   .   .   .   .   .3. Phase   .   .   .   .   .   .   .   .   .   .3. Wire   .   .   .   .   .   .   .   .   .   ..4. Output   .   .   .   .   .   .   .   .   .   .20   MV   dc.   open   circuit. Output   circuit   resistance   .   .4.97   ohms. Watts   per   element   .   .   .   .   .96.3. q.   Alternator. (1)  Stator  coils  winding  data  50/60  Hz. Type   .   .   .   .   .   .   .   .   .   .   .   3   phase. No.   of   slots   and   COils   .   .   .  84/84. Turns    per    coil.    .    .    .    .    .    .4. Coils   per   group   .   .   .   .   .   .7. Conductor.   .   .   .   .   .   .   .   .6   of   AWG   15. Span  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1-15  span. (2)  Rotor  coils  winding  data  50/60  Hz. Resistance    .    .    .    .    .    .    .    . Conductor    .    .    .    .    .    .    .    . Turns   per   coil.   .   .   .   .   .   . No.  of  poles  and  coils  .  .  . 0.390  ohm  at  25°C. 9 of AWG #16 (0.0508). 103. 4. (3)  Stator  coils  winding  data  400  Hz. Type    .    .    .    .    .    .    .    .    .    ..3    phase. No.   of   slots   and   coils   .   .   .  108/108. No.   of   coils   per   group   .   .   .36   groups   of   2, 36  groups  of  1, Turns  per  coil  .  .  .  .  .  .  .  .  .5. Span   .   .   .   .   .   .   .   .   .   .   .   l-4. Conductor.   .   .   .   .   .   .   .   .   AWG   16   and   AWG   17. (4)   Exciter   stator   winding   data. Type   of   winding   .   .   .   .   .   . No.   of   slots   and   coils   .   .   . No.  of  coils  per  group  .  .  . Turns   per   coil.   .   .   .   .   .   . Span   .   .   .   .   .   .   .   .   .   .   . Conductor    .    .    .    .    .    .    .    . salient   pole   dc. 10   slots,   10   coils. 1. 196. 1-2. 1 of AWG #21 (0.0285). 1 of AWG #22 (0.0253). (5)  Rotor  coils  winding  data  400  Hz. No.   of   poles   and   coils   .   .   .24. Turns    per    coil.    .    .    .    .    .    .30. Conductor.   .   .   .   .   .   .   .   .4   of   AWG   15. (6)   Exciter   rotor   winding   data. Type   of   winding   .   .   .   .   .   .3   phase. No.   of   slots   and   coils   .   .   .36   slots,   36   coils. No.   of   coils   per   group   .   .   .6   groups   of   2,   24 groups  of  1. Turns   per   coil.   .   .   .   .   .   .3   for   60/50   Hz,   5   for 400 Hz. Span   .   .   .   .   .   .   .   .   .   .   .   l-4. Conductor.    .    .    .    .    .    .    .    .  5 of AWG #16 (0.0508) 60/50  Hz.  3  of  AWG #16 (0.0508) 400 Hz. Insertion   sequence   .   .   .   .   .   211/112/111/121/111 and   repeat. r.  Engine  Repair  and  Replacement  Standards. Table   1-2   lists   manufacturer’s   sizes,   tolerances, and   maximum   allowable   wear   and   clearances. s.   Schematic   Wiring   Diagrams.   Figures   1-1 through  1-15   show   the   schematic   wiring   diagrams for  the  50/60  Hz  and  400  Hz  engine  generator  sets, as  well  as  schematic  and  wiring  diagrams  for  elec  - trical   assemblies,   relay   boxes   and   kits. t.    Torque    Values. (1)   Table   1-3   lists   specific   torque   values. (2)  All  torque  values  are  calculated  for  oil lubricated   threads.   Increase   this   value   by   10 percent   when   threads   are   not   lubricated. u.   Unit   Function   Differences.   The   engine   gener   - ator   sets   are   provided   in   three   configurations   accord- ing  to  class  and  mode  of  operation.   The   class   desig- nation  of  a  unit  is  determined  by  its  frequency  and voltage   performance   and   the   mode   designation   is dependent   upon   the   output   frequency.   Table   1-4 provides   a   quick   reference   for   determining   engine generator  set  classification  and  special  component complement   required. v.   Performance   Characteristics.   The   electrical performance  characteristics  for  Class  1  and  Class  2 sets  are  provided  in  tables  1-5  and  1-6. 1-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing