(b)  50/60  Hz  sets m.   Load   measuring  unit. DOD  drawing  No.  .  .  .  .  .70-1119. Input   voltage.   .   .   .   .   .   .   .114   -   139   volts,   50/60 Hz. Trip   frequency.   .   .   .   .   46   ±  1 H z    o r    5 5    H z ±  1  Hz: Voltage   input   limits   .   .   .   .   ±   10%. Temperature   range   .   .   .   .   -65°F   to   +   170°F. External   power   required   .   .   none. Contact   rating   .   .   .   .   .   .   .   10   amperes,   28   Vdc, resistive. (4)   Short   circuit   relay. DOD   drawing   No.   .   .   .   .   .70-1137. Trip   voltage   .   .   .   .   .   .   .   .24   volts   ±   1,   any   phase to   neutral. Contact   rating   .   .   .   .   .   .   .   10   amperes,   28   Vdc. Frequency.   .   .   .   .   .   .   .   .   50/400Hz. Temperature  range  .  .  .  .  -65°F  to  +  170°F. Temperature  effect  on  trip point   .   .   .   .   .   .   .   .   .   .  -65°F  to  +77°F  ±  2 percent  max.  change. +77°F to + 170°F ± 3 percent  max.  change. (5)   Reverse   power   relay. DOD  drawing  No.  .  .  .  .  .70-1136. DC   input   voltage   .   .   .   .   .   .   0/10   volts   with   ac voltage   superimposed on  dc  input  voltage  up to  20  volts. External   power   .   .   .   .   .   .24   volts   dc. Reverse   polarity   .   .   .   .   .   .   approx.   10   percent   re- verse  power. Temperature   limits   .   .   .   .   -65°F   to   +   170°F. Temperature  effect  on  trip point   .   .   .   .   .   .   .   .   .   .-650F   +   3volts   +   77°   F +  2  volts. + 170°F + 1.5   volts. Reverse  trip  voltage  .  .  .  .  +  2  volts. Contact   rating   .   .   .   .   .   .   .   10   amperes,   28   Vdc. (6)   Permissive   paralleling   relay. DOD  drawing  No.  .  .  .  .  .70-1118. External   power   required   .   .24   Vdc. Operating  level  .  .  .  .  .  .  contacts  close  when signal   input   voltage falls  below  8  volts  ± 1,   50/400   Hz. Temperature   limit   .   .   .   .   .   -65°F   to   +   170°F. Contact   rating   .   .   .   .   .   .   .28   volts,   10   amperes, resistive. DOD   drawing   No.   .   .   .   .   .69-785. Use   .   .   .   .   .   .   .   .   .   .   .   .  50  to  400  Hz  systems. n.   Contactor DOD   drawing   No.   .   .   .   .   . Construction    .    .    .    .    .    .    . KVA   rating   (maximum)   .   .   . Main   contacts   .   .   .   .   .   .   . Voltage   ac   .   .   .   .   .   .   .   . Frequency    .    .    .    .    .    .    .    . Continuous   current   .   .   .   . 6   second   current   .   .   .   .   . Interruption   (maximum)   .   .   . Mechanism   .   .   .   .   .   .   .   . Auxiliary    contacts: Voltage   dc Current Voltage   ac Lamp   current Contact  operation Temperature   range   .   .   .   . Coil   data Operating   voltage   (without (maximum)   .   .   .   .   .   .   . (minimum)   .   .   .   .   .   .   . Operating   time   at   voltage close    release    .    .    .    . Close   coil   resistance.   .   .   . 69-680. gasket   sealed. 125  KVA  50/60  and 400 Hz. 3  psi  +  (double  break). 120/208   and   240/416. 50/60  and  400  Hz. 350   amperes,   208 volts. 50/60  and  400 Hz. 750  amperes  at  50/60 and 400 Hz. 5000   amperes,   50/60 and  400  Hz. 120/208 volts   2500   amperes 50/60  and  400  Hz 240/416   volts. electrically   held. 28  volts. 7.5  amperes. 120  volts. 7.5  amperes. auxiliary    contacts operate  0.001  to 0.003   second   after main   contacts   close and   0.003   to   0.005 second   after   main contact   opens. 55°   to   71°C. external    resistance) 32  volts. 18  volts. 0.050/0.035     second at  30/18  Vdc. 8  ohms. o.  Thermal  Watt  Converter,  50/60  Hz. DOD  drawing  No.  .  .  . volts   .   .   .   .   .   .   .   .   . Current.    .    .    .    .    .    .    . Elements   .   .   .   .   .   .   . Phase    .    .    .    .    .    .    .    . Number  of  wires.  .  .  . Output . . . .. o.. Output   circuit   resistance Watts   per   element   .   .   . .  0  69-589-1. .    .  100/130. .   .  1   ampere. .   .  3. .   .  3. .   .  4. .   .  20  MV  dc,  open circuit. .   .  4.97   ohms. .   .  96.26. 1-4

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing