Exciter   Field   Voltage   and   Current   Versus   Load
Up
TM-5-6115-545-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Short   circuit   relay.

Capacity . . . .  .  .  .  .  .  .2.6  gpm  at  3600  rpm  at  320  psi. Rotation . . . . . . . . . . . clockwise. Type . . . . . . . . . . . . . .gear driven. Relief  valve  type.  .  .  adjustable. Relief  valve  setting.  .  .  .  310/330  psi. (5)  Turbocharger.  Refer  to  Operator  and Organizational   Maintenance   Manual. (6)   Electric   starter.    Refer  to  Operator  and Organizational  Maintenance  Manual. (7)   Battery   charging  alternator.   Refer   to Operator   and   Organizational   Maintenance   Manual (8)  Fuel  solenoid  valve. DOD drawing No . . . . . . . . . . 69-787-2 Volts . . . . . . . . . . . . . . . . . . .. Watts . . . . . . . . . . . . . . . . . .  .  . 10. Input pressure . . . . . . . . . . . 25 psi Orifice size . . . . . . . . . . . . . 1/4 in. (9)  Oil  pump. Type . . . . . . . . . . . . . . . . . . . gear driven. (10)   Oil   cooler. Refer   to   Operator   and Organizational    Maintenance    Manual. (11)   Water   pump. Refer  to  Operator  and Organizational    Maintenance    Manual. h.   Radiator:   Refer   to   Operator   and   Organizational Maintenance   Manual. i.   Safety   Devices: (1)  Coolant  high  temperature  switch.  Refer  to Operator   and   Organizational   Maintenance   Manual. (2)  Overspeed  switch.  Refer  to  Operator  and Organizational    Maintenance    Manual. (3)   Low   oil   pressure   switch.   Refer   to   Operator and   Organizational   Maintenance   Manual. (4)  Fuel  Level  Switch  (day  tank).  Refer  to Operator  and  Organizational    Maintenance    Manual. j.   Electric   Governor   Control   Unit   (400   Hz). DOD drawing No . . . . . . . . . . . 69-784-1 Type  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  solid  state Volts Input . . . . . . . . . . . . . . . .24 Vdc and 120 Vac from   generator. Control frequency. . . . . . . . . .400 Hz Power   dissipation.  . . . . . . . . .115 watts max. at 400 Hz. Frequency  regulation.  .  .  .  .  .  .0.25  percent. j .     G o v e r n o r     C o n t r o l     K i t     C l a s s i f i c a t i o n and   Rating Model  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  LEH Type . . . . . . . . . . . . . . . . . . . . . . solid   state volts   input . . . . . . . . . . . . . . . . . 24Vdc and 120 Vac from   generator. Control  frequency..  .  .  .  .  .  .  .  .  50/60  Hz. Power  dissipation.  .  .  .  .  .  .  .  .  .  .  .115  watts  max.  at 60 Hz. Frequency  regulation.  .  .  .  .  .  .  .  .0.25  percent. .   Relays, (1)  Overvoltage  relay. DOD drawing No . . . . . . . . . . . . . Nominal voltage . . . . . . . . . . . . . Time delay . . . . . . . . . . . . . . . . . Trip time . . . . . . . . . . . . . . . . . . . Contact rating . . . . . . . . . . . . . . . Temperature  limits.  .  .  .  .  .  .  .  .  . Temperature   effect   on pull-in voltage. . . . . . . . . . . . (2)    Undervoltage  relav. DOD drawing No . . . . . . . . . . . . . 70-1138 120   volts,   50-450   Hz. operates  at  153  +  3 volts   for   frequencies 50 to 450 Hz. operates  when  over  - voltage  condition  is sustained   for   a   mini- mum  of  200  mini- seconds. less   than   1.0   sec. after  voltage  reaches and  stays  at  pull-in value. 10  amperes,  28.5 volts,   resistive. -65°  F  to  +  170°  F. +77°  F  to  -  65°F decreases   min.   1 volt.  +  77°  F  to  +  170° F  changes  min.  +  1 volt . Nominal voltage. . . . . . . . . . . . . .120 volts, 50/400 Hz. Dropout voltage . . . . . . . . . . . . . .99 ±4 volts. Pull in voltage . . . . . . . . . . . . . . .110 + 3 volts. Time delay . . . . . . . . . . . . . . . . . .6+ 2 seconds at drop- out.  Instant  at  48  volts and  lower. Contact rating. . . . . . . . . . . . . . . 10 amperes, 28 volts, resistive. Contact  arrangement.  .  .  .  .  .  .  .  .2  pole  double  throw. Temperature . . . . . . . . . . . . . . . .- 65° to  +  170°  F. Temperature  effects  on  trip voltage . . . . . . . . . . . . . . . . . . . +77° F to-65°F ±l% max. + 77° F to 170° F + 1% max. (3)   Under   frequency   relays. DOD drawing No. . . . . . . . . . . .69-784-2 70-1120. DOD  Drawing  Numbers  : Governor  control  unit.  .  .  .  .  .  .  .  .  .  .81.-4903 agnetic  actuator  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  81-705 Magnetic  pickup  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .81-4904 Type: S o l i d    s t a t e Input  volts  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .ll-40vdc Frequency  regulation  .  .  .  .  .  .  .  .  .  .  .  .  0.  25% Temperature  range.  .  .  .  .  .  .  .  .  .  .  .  .  .  .-65°  to  185°  F Temperature  effect  on  trip (-55°   to   85°C) point . . . . . . . . . . . . . . . . . . . . . k.   Electric   Governor   Control   Unit   (50/60   Hz). (a)  400  Hz  sets. DOD drawing No . . . . . . . . . . . . . Input voltage . . . . . . . . . . . . . . . . Trip frequency . . . . . . . . . . . . . . Voltage input limits . . . . . . . . . Contact rating . . . . . . . . . . . . . . . Temperature range . . . . . . . . . . 70-1141. 120  volts  nominal (400  Hz.) 370 Hz ± 5. +  10%. 10   amperes,   28   volts resistive. -65°  F  to  ±  170°  F. - 65 °F to ± 77° F ± 1   Hz   max   change. +  77  F  to+  170°  F. Change 9 1-3