Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Tabulated Data
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure   1-12. Set   I.   D.   Plate
Up
TM-5-6115-545-12 Power Unit Utility Pack Gas Turbine Engine Driven (Air Research Model PPU85-5) Non-Winterized and (Air Research Model PPU85-4) Winterized Manual
Next
trouble shooting diagram

& Tabulated Data. (Cent) Amperes (above 30°F) . . . . . . . . . . . . . . . . . . . .. Start 14.5. run 5.0 Amperes (below 30 IF) . . . . . . . . . . . . . . . . . . . .. Start 17.5. run 7.5 Fuel consumption  . . . . . . . . . . . . . . . . . . . . . . . ..21 -23cc/min (700F) Duty cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..continuous (b).  Electric  winterization   kit. DOD drawing no . . . . . . . . . . . . . . . . . . . . . . . ...70-1299 Input power . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..205 t0240 volts 50/60 or 400 Hz single phase Current   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . ...14.6/12.5  amperes at 205/240 Vac Temperature    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermostat shut- off at 1500F +5° on at 130 °F~50 @ Wheel mounting  kit. DOD drawing no . . . . . . . . . . . . . . . . . . . . . . . ...70-1256 Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..50001bs Max speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..5mph onpaved surfaces Tmmangle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..40 °pivot Tire pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . ..60psi @  Load  bank. DOD drawing no . . . . . . . . . . . . . . . . . . . . . . . ...70-1271 Rating . . . . . . . . . .   . . . . . . . . . . . . . . . . . . . . . . . ..30KW Current   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64/42 amperes Input voltage   . . . . . . . . . . . . . . . . . . . . . . . . . . . ..120/2080r 240/416, 3-phase, 4 wire (16) Wiring diagrams. (figs. 1-13 thru 1-20: 1-29 and 1-30) (17)  Maintenance  and operating supplies. Refer to Appendix B  for a complete list of maintenance  and oper- ating supplies required  for initial operation. 1-5.  Difference  in  Models This manual covers generator sets model MEPO06A, MEP105A, and ME P1 15A. Model ME PO06A is a 50/60 Hz utility set (Class 2 Model MEP105A is a 50/60 Hz precise set (Class I Mode I), and model MEP115A is a 400 Hz precise set (Class I Mode II). The difference between precise  and utility 50/60 Hz and 400 Hz generator sets are noted in the appropriate  paragraphs through- out the manual. Figures 1-26 and 1-27 show the harness intercon- nection for these models. These differences are summarized  as follows: ~ The generator used on models MEPO06A and MEP105A is a 50/60 Hz generator. That used in Model MEP115A is a 400 Hz generator. ~ The governor  used on model MEP105A is an electro- hydraulic  governor  consisting of a governor  control  unit, load measuring unit and hydraulic  sump, filter, pump and actuator (See fig. 1-28). An electric governor  is used on model MEP115A. The governor  control  unit on MEP105A is 50/60 Hz, and 400 Hz on MEP1 15A. The load measuring unit however is used on all models. Frequency is controlled by a rheostat on the control panel on MEP115A and MEP105A unit. The governor  used on model MEPO06A is a mechanical governor  which is integral with the fuel injection  pump. Frequency is adjusted by a manual speed control. g The same special relay box is used on models ME P105A and MEPO06A, but model MEP105A also has a precise relay box. The precise relay box contains a frequency selector switch, under frequency relay, undervoltage relay, permissive paralleling  relay, governor  feedback capacitor and frequency adjust fixed resistors. The special relay box used on model MEP1 15A contains the same components  as that used on models ME PO06A and ME P105A, and also those contained  in the precise relay box with the excep tion of the frequency selector switch. < The control  cubicle  contains some componets which are different on the various  models. g The exciter regulator assembly and the cross current transformer, on the current  transformer assembly, are different on model MEP1 15A to those on the other two models. & The differences in performance characteristics of the various models are shown in table 1-1. Change  11 1-15/(1-16    blank)

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing