Tabulated Data
Up
TM-5-6115-465-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Tabulated Data (cont)

TM 5-6115-465-34
TO 35C2-3-446-2
NAVFAC P-8-625-34
TM 06858B/06859D-34
Temperature range . . . . . -65°F (-58.8°C) to
Contact rating . . . . . . 10 amp, 28V, resistive
170°F (76.7°C)
Contact arrangement . . . . 2 pole, double throw
Variation of actuation
Temperature range . . . . . -65°F (-58.5°C) to
point over temperature
+170°F (76.7°C)
range . . . . . . . . . . Less than 1 Vac
Trip voltage variation
Contact rating . . . . . . 10 amp, 28 Vdc,
over temperature
resistive
range . . . . . . . . . .± 2% max.
Thermal Watt Converter Classification and
i.  Underfrequency Relay Classification and
Rating.
Rating.
DOD drawing number:
DOD drawing number:
50/60 Hz . . . . . . . . 69-589-1
50/60Hz . . . . . . . . 70-1119
400 HZ . . . . . . . . . 69-589-2
400 Hz . . . . . . ...70-1141
Operating voltage . . . . . 100 to 130 Vac
Input voltage (nominal) . . 120 Vac
Current. . . . . . . . . . 1 amp
Trip frequency:
Elements . . . . . . . . .3
400 Hz . . . . . . . . .370 ± 5 Hz
Phase. . . . . . . . . . .3
60 Hz . . . . . . . . . .48 ± 3 Hz
Number of wires . . . . . . 4
50 Hz . . . . . . . . . .43 ± 3 Hz
Output . . . . . . . . . . 20 MVdc, open circuit
Voltage input limits . . . + 10 percent
Circuit resistance
Temperature range . , . . . -65°F (-58.5°C) to
(output) . . . . . . . . . 4.97 ohm
+170°F (76.7°C)
Watts per element:
Trip frequency
50/60Hz . . . . . . . .96.26
variation over
temperature range . . . . ± 2 Hz
400 Hz . . . . . . . . .96.3
j.  Short Circuit Relay Classification and
n.  Main Load Contactor Contactor Classifica-
Rating.
tion and Rating.
. . . . 72-2256
DOD drawing number
DOD drawing number . . . . 69-680
Trip voltage . . . . . . . 10 ± Vac (any phase to
Enclosure . . . . . . . . . Gasket sealed casing
neutral)
KVA. . . . . . . . . . . . 125 (max)
Contact rating . . . . . . 10 amp, 28 Vdc
Main contact type . . . . . Double break, magnetic
Frequency range . . . . . . 50 Hz to 450 Hz
Voltage range . . . . . . . 120 Vac to 416 Vac
Temperature range . . . . . -65°F (-58.5°C) to
Frequency range . . . . . . 50 Hz to 400 HZ
170°F (76.7°C)
Continuous current . . . . 350 amp
Trip variation over
temperature range  . . . . 5 percent maximum
Interruption current . . . 5000 amp (max)
k.  Reverse Power Relay Classification and
Auxiliary contacts:
Rating.
Operating voltage . . . . 28 Vdc
DOD drawing number . . . . 72-2255
Operating current . . . . 7.5 amp
DC input voltage . . . . . 0 to 1O Vdc
AC voltage . . . . . . . 120 Vac
AC superimposition . . . . Up to 20 Vac
Lamp current . . . . . . 7.5 amp
Reverse polarity . . . . . 20 percent
Operational lag
(approximate)
behind main
contacts . . . . . . . . . 0.001 to 0.003 sec.
Temperature range . . . . . -65°F (-58.8°C) to
170°F (76.7°C)
Coil data:
Variations in trip
Operating voltage . . . . 18 to 30 Vdc
voltage over
Actuation time . . . . . 0.035 to 0.050 sec.
temperature range . . . . ± 3 Vdc (max)
Close coil resistance . . 8 ohm
Contact rating . . . . . . 10 amp, 28 Vdc,
resistive
50/60 Hz Generator Classification and
Rating.
1.  Permissive Paralleling Relay Classification
and Rating.
Rating . . . . . . . . . .30 KW
DOD drawing number . . . . 70-1118
Kilovolt amperes:
Input power . . . . . . . . 24 Vdc
1500 rpm (50 Hz) . . . . 18.75
Actuation point . . . . . . 8 ± 1 Vac (falling)
1800 rpm (60 Hz) . . . . 15.63
Frequency range . . . . . . 50 Hz to 400 HZ
Change 5
1-4