Click here to make tpub.com your Home Page

Page Title: Tabulated Data
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Section II. DESCRIPTION AND DATA
Up
TM-5-6115-465-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Tabulated Data (cont)

TM 5-6115-465-34
TO 35C2-3-446-2
NAVFAC P-8-625-34
TM 06858B/06859D-34
Overshoot/undershoot:
Starter Assembly Classification and Rating.
c.
MEP-005A . . . . . . . 20% rated voltage
Stalled current . . . . . . 500 amps (max)
MEP-104A . . . . . . . 15% rated voltage
Stalled torque . . . . . . 18 lbs. - ft. (min)
MEP-114A . . . . . . . 12% rated voltage
Duty classification . . . . 15 sec on - 15 sec off
(2 starting cycles per
f. Governor Control Unit Classification and
minute)
Rating.
Drive type . . . . . . . . Positive indexing with
DOD Drawing Numbers:
overrun clutch
50/60 Hz . . . . . . . . 69-784-2
d.  Fuel Injector Pump Classification and
Rating.
400 HZ . . . . . . . . .81-49O3
Type . . . . . . . . . . .Solid state
Manufacturer . . . . . . . Hartford Machine Screw
Co., Div. of Standard
Input volts . . . . . . . . 24 Vdc and 120 Vac
Screw Co., Inc.
Frequency regulation . . . 0.25%
Model . . . . . . . . . . . DBGFC633X1LK
Power dissipation . . . . . 115 watts (max)
Line pressure . . . . . . . . 2500 to 2950 psig
Enclosure . . . . . . . . . Water-proof, wax-filled
Transfer pump pressure. . . 130 psig (max)
casing
Transfer pump lift . . . . 15 in. HG (min)
f.1 Governor Control Kit Classification and
Rating.
Full load rpm . . . . . . .l8OO
Delivery variation
DOD Drawing numbers:
between cylinders at
Governor control unit . . . 81-4903
full load . . . . . . . . 5% (max)
Magnetic actuator . . . . . 81-705
e.  Static Exciter and Voltage Regulator
Magnetic pickup . . . . . . 81-4904
Assembly Classification and Rating.
Solid state
Type . . . . . . . . . . . Solid state
Type:
Voltage regulation:
Input volts . . . . . . . . 11-40 Vdc
Frequency regulation . . . 0.25%
MEP-005A . . . . . . . . 3% of rated voltage
MEP-104A . . . . . . . . 1% of rated voltage
Temperature range . . . . . -65° to 185°F
(-55° to 85°C)
MEP-114A . . . . . . . . 1% of rated voltage
9"  Overvoltage Relay Classification and
Voltage stability:
Rating.
Short term:
DOD Drawing number  . . . . 72-2257
MEP-005A . . . . . . . Within 2% of rated
Nominal voltage . . . . . . 120 Vac
voltage
Actuation voltage . . . . . 153 ± 3 Vac over fre-
MEP-104A . . . . . . . Within 1% of rated
quency range of 50 to
voltage
450 Hz
MEP-114A . . . . . . . Within 1% of rated
Time delay . . . . . . . . 200 m sec sustained
voltaqe
overvoltage (rein)
Long term:
Trip time . . . . . . . . . Less than 1.0 sec.
MEP-005A . . . . . . . Within 4% of rated
after sustained pull-
voltage
in voltage
MEP-104A . . . . . . . Within 2% of rated
Contact rating . . . . . . 10 drop, 28.5V,
Voltage
resistive
MEP-114A . . . . . . . Within 2% of rated
Temperature range . . . . . -65°F (-58.5°C) to
voltaqe
+ 170°F (76.7°C)
Voltage drift (8 hour
h.  Undervoltage Relay Classification and
period, with tempera-
Rating.
ture variation of up
. . . . 70-1120
DOD drawing number
to 60°F)(15.5°C) . . . . 1%
Nominal voltage . . . . . . 120 Vac
Transient performance:
Frequency range . . . . . . 50 to 450 Hz
Resumption of steady state:
. . . . . 99 ± 4 Vac
Drop-out voltage
MEP-005A . . . . . . . Within 3 sec.
Pull-in voltage . . . . . . 110 ± 3 Vac
MEP-104A . . . . . . . Within O.5 sec.
Time delay . . . . . . . . 6 ± 2 sec. after drop-
MEP-114A . . . . . . . Within O.5 sec.
it (instantaneous at
40 Vac and below)
Change
5
1-3

Privacy Statement - Press Release - Copyright Information. - Contact Us