![]() ![]() TM 5-6115-400-35
C1
}
Change
HEADQUARTERS
DEPARTMENT OF THE ARMY
No. 1
Washington, D.C., 13 July 1970
Direct and General Support and Depot Maintenance Manual
GENERATOR SET, DIESEL ENGINE: 200 KW, 60 CYCLE, AC, 120/208V, 240/416V,
3 PHASE CONVERTIBLE TO 167 KW, 50 CYCLE, 120/208V, 240/416V, 3 PHASE,
MULTI-PURPOSE, PORTABLE; SKID MOUNTED,
(MILITARY DESIGN MODEL SF-200-MD/CIED)
FSN 6115-999-7901
Page 38, paragraph 34c(18), line 1, "Holder (66)" is
TM 5-6115-400-34, 13 February 1968, is changed as
follows:
changed to read "Holder (65)".
All references to "cycles" throughout this manual is
Page 40, figure 15. Move callout 9, leader line from
changed to read "hertz".
housing assembly to plug.
Page 1. Table of Contents. Add "Appendix I,
Page 43, paragraph 34ql), line 2, "(64, fig. 15)" is
References, Page 181," and Index, Page 183-193" after
changed to read "(65, fig. 15)".
last item on page.
Page 45, paragraph 34g(4), line 2 "(64, fig. 15)" is
Page 18, paragraph 5, lines 3 and 4 "and the
changed to read "(65, fig. 15)".
applicable appendix in this manual" is changed to read
Page 49, paragraph 35c(21), line 1 "weight bushings
"and in TM 5-6115-400-25P".
(24)" is changed to read "weight bearings (24)".
Page 14, paragraph 6. Line 2, "Repair Parts are
Page 62, paragraph C3, line 2, "securely" is changed
illustrated and listed in Appendix II" is changed to read
to read "to 100 ft. lb. torque".
"Repair parts are illustrated and listed in TM 5-6115-
Page 116, paragraph 53e(2), line 3, "torque of 16- to
400-25P".
170- ft. lbs." is changed to read "torque of 160- to 170-
Page 30, paragraph 32c, line 9, "lead rheostat" is
ft. Ibs."
changed to read "load rheostat".
1
|
|