TM 5-3810-306-34
LENGTH/ANGLE CABLE REEL ASSEMBLY INSTALLATION
TOOLS:
Level ( ) 2 required
SUPPLIES: None
EQUIPMENT CONDITIONS:
Negative battery cable disconnected at shunt. (Refer to TM 5-3810-306-20.)
Boom fully retracted and lowered. (Refer to TM 5-3810-306-10.)
e. Cut tie wraps holding length cable (6) around
REMOVAL:
tube (8). Remove length cable (6).
1. CLAMP CABLE DRUM (1) ONTO MOUNTING
3. CAREFULLY RELEASE CLAMP ON CABLE DRUM
BRACKET (2) TO PREVENT PREMATURE
(1) AND RETRACT LENGTH CABLE (6) ONTO
RETRACTION OF LENGTH CABLE (6).
DRUM. SECURE FREE END OF LENGTH CABLE
(6) TO CABLE DRUM (1) WITH TAPE.
2. REMOVE LENGTH CABLE (6) FROM BOOM NOSE
RECEPTACLE (4).
NOTE
a. Unplug jumper/dummy plug (3) from boom nose
receptacle (4).
Cable drum (1) will still be under
tension when length cable (6) is fully
b. Loosen set screws (5) and separate insert (18)
retracted. Carefully turn cable drum
from boom nose receptacle (4).
(1) until tension is gone.
c. Disconnect the core wire of length cable (6) from
4. REMOVE
LENGTH/ANGLE
CABLE
REEL
pin 6 and the shield of length cable (6) from
ASSEMBLY (16).
ground terminal on insert (18).
a. Remove hex screws (9), washers (10) and cover
NOTE
(11) from cable reel assembly (16).
Do not remove wire No. 2 (A2B
b. Tag and disconnect wires of cable (12) from
Switch) from Pin 6.
terminal block in cable reel assembly (16).
d. Loosen connector nut (7) and pull length cable
c. Loosen connector nut (13) and pull cable (12)
(6) from boom nose receptacle (4).
from cable reel assembly (16).
NOTE
d. Remove bolts (14), washers (15) and cable reel
assembly (16) from mounting brackets (2).
Before cutting tie wraps, make note
of how many times length cable (6) is
wrapped around tube (8).
14-10