TM 5-3810-306-34
a. Remove setscrew (9) from housing (16).
WARNING (CONT'D)
b. Screw 1/8" -24 machine screw into end of check
flash point is 100F-138F (38-59 C).
ball seat (11). Pull screw and seat (11) out with
If you become dizzy while using
pliers.
cleaning solvent, get fresh air
immediately and get medical aid. If
c.
Remove and discard seals (10) and (12) from
contact with eyes is made, wash your
seat (11).
eyes with water and get medical aid
immediately.
Dry parts with
d. Tip housing (16) and remove check ball (13) and
compressed air. Do not wipe dry with
check ball retainer (14).
cloth or paper towel because lint or
other matter can get into hydraulic
CLEANING:
system
and
cause
damage.
Compressed air used for cleaning
WARNING
purposes will not exceed 30 psi. Use
only with effective chip guarding and
Dry cleaning solvent P-D-680 is toxic
personal
protective
equipment
and flammable.
Wear protective
(goggles/ shield, gloves, etc.).
goggles and gloves and use only in a
well ventilated area. Avoid contact
1. CLEAN ALL PARTS WITH SOLVENT P-D-680 AND
with skin, eyes, and clothes and do
BLOW DRY WITH COMPRESSED AIR.
not breathe vapors. Do not use near
open flame or excessive heat. The
10-5