TM 5-3810-306-34
TABLE 3-1. DIRECT AND GENERAL SUPPORT TROUBLESHOOTING (CONTD)
Malfunction
Test or Inspection
Corrective Action
94.
ERROR CODE E13 DISPLAYED ON CONSOLE
Step 1. Fallen below lower limiting value for measuring channel (pressure - rod side).
a.
Check cable and plug from CPU to pressure transducer. (Refer to Malfunction No. 86.) Replace as
necessary.
b.
Replace defective pressure transducer (rod side). (Refer to page 14-20.)
c.
95.
ERROR CODE E15 DISPLAYED ON CONSOLE
Step 1. Fallen below lower limiting value for the measuring channel (angle - main boom).
a.
Check cable from CPU to length/angle sensor. (Refer to Malfunction No. 85.) Replace as necessary.
b.
Replace defective length/angle cable reel. (Refer to page 14-10.)
c.
96.
ERROR CODE E19 DISPLAYED ON CONSOLE
Step 1. Error in reference voltage.
a.
b.
Check external load moment indicator wiring for short circuit. Repair as necessary.
3-60