TM 10-3930-675-24-2
TOPHANDLER REPLACEMENT - CONTINUED
0189 00
INSTALLATION - CONTINUED
NOTE
Install the hose with the large female quick disconnect fitting first. It will be necessary to bleed off the
residual oil in the hose by rocking it back and forth on the male fitting before the fitting will connect.
Use plenty of rags to catch the bled off oil.
8.
Remove caps/plugs and connect six hydraulic hose quick disconnect fittings (10) to top of tophandler.
10
434-40074
9.
Connect four electrical connectors (8) to bottom of tophandler junction box (9).
9
8
434-40075
0189 00-13