TM 9-2320-312-24-2
Systems Operation Section
Fuel Transfer Pump
Some engines use Engine Control Modules
(ECM) (15) with a replaceable computer chip.
The software has already been installed in the
Fuel transfer pump (35) is mounted on the back of
replaceable computer chip. The 3126B and 3126E
unit injector hydraulic pump (1). The fuel transfer
diesel truck engines do not have a replaceable
pump is used in order to draw fuel from fuel tank
personality module. The 3126B and 3126E diesel
(12). Also, the fuel transfer pump is used in order
truck engine's personality module are a permanent
to pressurize the fuel to 450 kPa (65 psi). The
part of the ECM. The 3126B and 3126E diesel truck
pressurized fuel is supplied to injectors (7).
engine's personality module can be reprogrammed.
Reprogramming of the personality module requires
Fuel transfer pump (35) is a single piston pump
the use of Caterpillar Electronic Technician (Cat
that is spring loaded. The shaft of the unit injector
ET). The flash function of Cat ET will be used during
hydraulic pump provides power to the transfer
the reprogramming.
pump through an off-center bearing. There are two
check valves in the fuel transfer pump. The inlet
ECM (15) logs faults of engine performance. Also,
check valve opens in order to allow fuel from the
the ECM is capable of running several diagnostic
tank into the pump. The inlet check valve closes in
tests automatically when the ECM is used with an
order to prevent fuel leakage back to the fuel tank.
electronic service tool such as the Cat ET.
The outlet check valve opens in order to supply fuel
to the fuel supply passage. The fuel supply passage
is located in the cylinder head. The fuel supply
Unit injector hydraulic pump
passage supplies fuel to injectors (7). The outlet
check valve closes in order to prevent pressurized
Unit injector hydraulic pump (1) (high pressure
fuel leakage back through the pump.
oil pump) is located at the left front corner of the
engine. The unit injector hydraulic pump is a piston
Injection Actuation Pressure Sensor
pump that has a fixed displacement. The unit
injector hydraulic pump uses an axial piston. The
(IAP)
unit injector hydraulic pump uses a portion of the
engine lubrication oil. The unit injector hydraulic
IAP Sensor (6) is installed in the high pressure oil
pump pressurizes the engine lubrication oil to the
manifold. The high pressure oil manifold supplies
injection actuation pressure that is required in order
actuation oil in order to power the unit injectors. The
to power the HEUI injectors.
IAP Sensor monitors injection actuation pressure.
The IAP Sensor sends a continuous voltage signal
Injection Actuation Pressure Control
back to ECM (15). The ECM interprets the signal.
The ECM is aware of the injection actuation pressure
Valve (IAP Control Valve)
at all times.
Injection actuation pressure control valve (10) (IAP
Control Valve) is located on the side of unit injector
hydraulic pump (1). Under most conditions, the
pump is producing excess oil flow. The IAP Control
Valve discharges excess pump flow to the drain
in order to control injection actuation pressure to
the desired level. The IAP Control Valve is a valve
of high precision that controls the actual actuation
pressure. The performance maps of ECM (15)
contain a desired actuation pressure for every
engine operating condition. The ECM sends a
control current to the IAP Control Valve. The control
current should make the actual actuation pressure
equal to the desired actuation pressure.
IAP Control Valve (10) is an actuator. The IAP
Control Valve converts an electrical signal from
ECM (15) to the mechanical control of a spool valve
in order to control pump outlet pressure.