![]() ![]() TM 5-2420-222-20-1
INDICATOR AND WARNING ELECTRICAL CIRCUITS
AC GENERATOR INDICATOR LIGHT
·
Negative terminal connected by wire to ac generator voltage regulator.
·
Positive terminal connected by wire to battery and ac generator output voltage through ignition lock switch ACC
terminal and 20 ampere circuit breaker, and to other indicators and light switch.
·
Senses electrical system current and shows when ac generator is not charging.
ENGINE OIL PRESSURE INDICATOR LIGHT
·
Positive terminal connected by wire to negative terminal of ac generator indicator light and positive terminal of
FUEL level gage.
·
Negative terminal connected by wire to positive terminal of engine oil pressure switch.
·
Lights up to get operator's attention when engine oil pressure switch closes due to drop in engine oil pressure
below a preset point during engine operation.
ENGINE OIL PRESSURE SWITCH
·
Positive terminal connected by wire to negative terminal of engine oil pressure indicator light.
·
Grounded through housing to flywheel housing.
·
Normally closed switch is kept open by oil pressure during engine operation as long as engine lubrication system
pressure is above a preset level. When engine oil pressure drops below preset level, switch closes and engine oil
pressure indicator light lights up.
TA242689
1-24
|
|